Textbook Question
Chapter 18, Problem 2PA
You are working on a residential heat pump. The heat pump is connected to a 240-V, 60-Hz power line. The compressor has a current draw of 34 amperes when operating. The compressor has a power factor of 70%. The backup strip heat is rated at 10 kW. You need to know the amount of total current draw that will occur if the strip heat comes on while the compressor is operating.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
In a closed cycle gas turbine, there is two stage compressor and two-stage
turbine. All the components are mounted on the same shaft. The pressure
and temperature of air at inlet to the first stage compressor are 1.5 bar
and 20°C respectively. The maximum cycle pressure and temperature are
limited to 750°C and 6 bar. A perfect intercooling and reheating are used
between the compressors and the turbines. A regenerator whose
effectiveness is 0.7 was employed. Assuming the compressors and
turbines efficiencies as 0.82, calculate:
a. Thermal efficiency of the cycle.
b. Mass of working fluid for a power output of 350 kW.
Assume the working fluid is air has Cp = 1.005 kJ/kg K, y = 1.4.
Question 2. Considering this figure. The firing
angle is 45°, the motor current is 10 A, and the supply
voltage is 110 v.
0₁ 0₂
90
(a) Draw the waveforms of v, Vo. io. isi, iDi, and i.
(b) Determine the power taken by the dc motor.
(c) Determine the supply volt-amperes and supply power factor. Assume
that the converter is lossless.
(d) Determine the rms value of the SCR current and the diode current.
We know there are few conditions for alternator synchronization. How many conditions are there? Write all the conditions.
Chapter 18 Solutions
Delmar's Standard Textbook Of Electricity
Ch. 18 - 1. When an inductor and a resistor are connected...Ch. 18 - 2. An inductor and resistor are connected in...Ch. 18 - 3. What is the impedance of the circuit in...Ch. 18 - 4. What is the power factor of the circuit in...Ch. 18 - How many degrees out of phase are the current and...Ch. 18 - 6. In the circuit shown in Figure 18-1, the...Ch. 18 - 7. A resistor and an inductor are connected in...Ch. 18 - The R-L parallel circuit shown in Figure 18-1 has...Ch. 18 - The R-L parallel circuit shown in Figure 18-1 has...Ch. 18 - How many degrees out of phase are the total...
Ch. 18 - Incandescent lighting of 500 W is connected in...Ch. 18 - You are working on a residential heat pump. The...Ch. 18 - Assume that the circuit shown in Figure 18-1 is...Ch. 18 - Assume that the current flow through the resistor,...Ch. 18 - Assume that the circuit in Figure 18-1 has an...Ch. 18 - Assume that the circuit in Figure 18-1 has a power...Ch. 18 - In an R-L parallel circuit, R=240 and XL=360. Find...Ch. 18 - In an R-L parallel circuit, IT=0.25 amps, IR=0.125...Ch. 18 - In an R-L parallel circuit, ET=120 volts,...Ch. 18 - In an R-L parallel circuit, ET=48 volts, IT=0.25...Ch. 18 - In an R-L parallel circuit, ET=240 volts, R=560 R...Ch. 18 - In an R-L parallel circuit, ET=240 volts, R=560,...Ch. 18 - In an R-L parallel circuit, ET=208 volts, R=2.4k,...Ch. 18 - In an R-L parallel circuit, ET=480 volts, R=16,...Ch. 18 - In an R-L parallel circuit, IT=1.25 amps, R=1.2k,...Ch. 18 - In an R-L parallel circuit, true power =4.6 watts...Ch. 18 - An R-L parallel circuit is connected to 240 volts...Ch. 18 - An R-L parallel circuit has an applied voltage of...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A generator is feeding the load. A second load will then be connected in parallel with the first load. The generator has an idle frequency of 61Hz and an Sp slope of 1MW/Hz. Load2 draws 800kW active power at 0.707 reverse power factor, while load1 draws 1000kW active power at 0.8 reverse power factor. What will be the operating frequency of the system after load 2 is connected? *Please explain the solution step by steparrow_forwardComment briefly on the relationship between input and output power at varying excitation levels and on the relationship between excitation and power factor or reactive power, when the synchronous machine is connected to an infinite busbararrow_forwardUntitled Section Jalis 6 In d.c. generators armature reaction is produced by field current O armature current commutating winding current none of the mentioned compensating winding current *.The use of d.c. generators eliminated the use of rectifiers and ac supplies True False Oarrow_forward
- is the maximum operational speed of the wind turbine at which the turbine should be shut down to avoid structural failure. O rated speed O cut in speed cut out speed O maximum speedarrow_forwardA four-pole induction motor drives a load at 2575 rpm. This is to be accomplished by using an electronic converter to convert a 400-V dc source into a set of three-phase ac voltages. ▾ Part A Find the frequency required for the ac voltages assuming that the slip is 4 percent. The load requires 2 hp. Express your answer to three significant figures and include the appropriate units. f= Submit ▾ Part B Value μÀ Submit I= Value Provide Feedback ^ Request Answer If the dc-to-ac converter has a power efficiency of 85 percent and the motor has a power efficiency of 80 percent, estimate the current taken from the dc source. Express your answer to three significant figures and include the appropriate units. 4 Ò Request Answer Units ? Units ?arrow_forwardQuestion 1 A 125 MVA, 20 kV, three-phase, wye-connected, 60 Hz, synchronous alternator is connected to a 20 kV power grid. The alternator has negligible armature resistance and synchronous reactance of 5 2/phase. The mechanical limit of the turbine powering the alternator limits its maximum power output to 100MW. (a) Calculate the value of excitation voltage (line to neutral with angle) needed for 50% maximum power (50MW) at unity pf. |E(LN) 8 (b) Find the alternator reactive power import/export if its real power output is now increased to 75% rated (75 MW) with the excitation unchanged. (1) Draw before and after phasor diagrams on the same axes (performance chart) to illustrate the two operational states. (ii) Calculate the alternator reactive power import/export when its real power output is increased to 75% rated (75 MW) with the excitation unchanged. Q3ph Import or export?arrow_forward
- Q-4 100 MVA, 50 Hz alternator is operating at rated speed. The H constant of the machine is 5 MJMVA. The load suddenly increases by 50 MW. Due to delay in governor action, there is a delay of 0.5 sec in opening of steam value. The frequency deviation in percentage isarrow_forwardfast please answer in 10 minutes 3 phase synchronous motor connected to an infinite bus is operating with normal Excitation with decrease in load A Armature current decreases B. p.f. becomes legging C. Power factor becomes leading D. Load angle decreases E. Reactive power flows from motor to bus F Reactive power flows from bus to motor From this the correct answer is a. A, B, D, F b. A, B, D c. B, D, E d. C , D, Earrow_forwardA field excitation of 20 A in a certain alternator results in an armature current of 400 A in short circuit and a terminal voltage of 2000 V on open circuit. The magnitude of the internal voltage drop within the machine at a load current of 200 A isarrow_forward
- Two identical 2,000 kW alternator operates in parallel. The governor of the first machine is such that the frequency drops uniformly from 50 Hz at no-load to 48 Hz at full-load. The corresponding uniform speed drop of the second machine is 50 Hz to 47.5 Hz. What is the maximum load that can be delivered without overloading either machine?arrow_forwardWhy do you keep the alternator speed constant in this experiment?arrow_forward2 Compare between base load pbiney stvion and peak load power station.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Boost Converters and Buck Converters: Power Electronics; Author: Physics Videos by Eugene Khutoryansky;https://www.youtube.com/watch?v=vwJYIorz_Aw;License: Standard Youtube License