Programmable Logic Controllers
Programmable Logic Controllers
5th Edition
ISBN: 9780073373843
Author: Frank D. Petruzella
Publisher: McGraw-Hill Education
bartleby

Concept explainers

Question
Book Icon
Chapter 13, Problem 13P
Program Plan Intro

Suspend (SUS) instruction:

  • The SUS instruction refers to a diagnostic instruction.
  • It is used to trap and identify specific conditions for program debugging as well as for system troubleshooting.
  • It is also used to diagnose the ladder logic program for trouble shooting by placing the controller in suspend or idle mode.

Blurred answer
Students have asked these similar questions
Develop ladder logic programming for a parking area with 100 slots. Use counters for the application Provide the following Allocation list Grafcet Equation Ladder program
A binary to 8-segment display controller will be designed to guide patients based on their body temperature. If the patient body temperature is above or equal to 38°C, the display will indicate , and it will display - otherwise. Block diagram of the complete system is shown in Fig. 1. In order to turn on a segment the corresponding control output of the controller is set to logic-1. 1) Fill in the truth table given in Fig. 2. b) a) The circuits for c0, cl and c4 will be implemented by using 8-to-1 MUXS and AND, OR, NOT gates. Draw the circuits for c0, cl and c4. The circuits for c2, c3 and c6 will be implemented by using NAND gates. Draw c) the circuits for c2, c3 and c6. A BCD EFC0 c1 1 00 0 0 0 100 0 0 1 1 0 0 0 1 0 1000 1 1 1001 0 0 1 001 0 1 1 0 01 10 001 1 1 1 0 1 0 00 0 1 0 0 1 0 10 10 0 1 01 1 101 1 00 0 1 1 0 1 0 1 1 1 0 11 1 c2 c3 c4 c5 c6 c7 c5 Sc6 c7 c2 c0 cl c2 c3 c4 c5 có c7 Binary to 8-segment controller 1 干tfff↑ А всD E F 1 1 1 1 1 1 Figure 1 Figure 2
3. Design a logic circuit that controls an elevator door in a three-story building. M is a logic signal that indicates when the elevator is moving (M = 1) or stopped (M = 0). F1, F2, and F3 are floor indicator signals that are normally LOW, and they go HIGH only when the elevator is positioned at the level of that particular floor. For example, when the elevator is lined up level with the second floor, F2 = 1 and F1 = F3 = 0. The circuit output is the OPEN signal, which is normally LOW and will go HIGH when the elevator door is to be opened. We can fill in the truth table for the OPEN output as follows: a. Because the elevator cannot be lined up with more than one floor at a time, only one of the floor inputs can be HIGH at any given time. This means that all those cases in the truth table where more than one floor input is a 1 are don't-care conditions. We can place an x in the OPEN output column for those eight cases where more than one F input is 1. b. Looking at the other eight…
Knowledge Booster
Background pattern image
Computer Science
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, computer-science and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Database System Concepts
Computer Science
ISBN:9780078022159
Author:Abraham Silberschatz Professor, Henry F. Korth, S. Sudarshan
Publisher:McGraw-Hill Education
Text book image
Starting Out with Python (4th Edition)
Computer Science
ISBN:9780134444321
Author:Tony Gaddis
Publisher:PEARSON
Text book image
Digital Fundamentals (11th Edition)
Computer Science
ISBN:9780132737968
Author:Thomas L. Floyd
Publisher:PEARSON
Text book image
C How to Program (8th Edition)
Computer Science
ISBN:9780133976892
Author:Paul J. Deitel, Harvey Deitel
Publisher:PEARSON
Text book image
Database Systems: Design, Implementation, & Manag...
Computer Science
ISBN:9781337627900
Author:Carlos Coronel, Steven Morris
Publisher:Cengage Learning
Text book image
Programmable Logic Controllers
Computer Science
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education