Elements Of Electromagnetics
7th Edition
ISBN: 9780190698614
Author: Sadiku, Matthew N. O.
Publisher: Oxford University Press
expand_more
expand_more
format_list_bulleted
Question
Water at 15°C is supplied to a one-shell-pass, two-tube-pass heat to cool 10 kg/s of liquid ammonia from 120°C to 40°C. You anticipate a U on the order of 1500 W/m2K when the water flows in the tubes. If A is to be 90m2, choose the correct flow rate of water.
Question from A Heat Transfer Textbook, 5th Edition, Problem 3.17
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 5 steps with 1 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Consider two heat exchanger configurations: parallel-flow and counter-flow. For both configurations cooling water at a flow rate of 1.5 kg/s enters the heat exchanger at 30°C and exits at 45.1°C. This water cools unused engine oil at a flow rate of 1 kg/s from 95°C to 50°C. Both configurations have the same overall heat transfer coefficient of 9,000 W/m2/K. Determine the following: 1. What is the required heat transfer area for each configuration? 2. Give that both configurations have the same inlet and outlet temperatures, what is the basis of the different areas calculated in part a?arrow_forwardQuestion #7 Steam at 320°C flows in a stainless steel pipe (k-15W/m K) whose inner and outer diameter are 5cm and 5.5cm respectively. The pipe is covered with 3cm thick glass wool insulation (-0.038W/mK). Heat is lost to the surroundings at 5°C by natural convection and radiation, with a combined natural convection and radiation heat transfer coefficient of h 15W/m² K. Taking the heat transfer coefficient inside the pipe to be happe = outside pipe = 80 W/m²K. (A) Draw the schematic diagram of this problem and label all quantities. (B) Draw the thermal network diagram of this problem and label all thermal resistors and the direction of heat flow. (C) Determine the (i) inner surface area (ii) outer surface area (iii) inner thermal resis- tance (iv) outer thermal resistance (v) thermal resistance across pipe and (vi) thermal resistance across insulation. (D) Determine the total thermal resistance for the unit length of pipe. (E) Determine the rate of heat loss from the steam per unit…arrow_forwardAn incompressible fluid flows through a rectangular cross section duct, with width much larger than height of the cross section. The duct surface is heated at a uniform rate along its length. If the centreline of the flow is along the centre of the duct where y = 0, the distance from the centreline to the surface of the duct is b = 25 mm, and the thermal conductivity of the fluid is 0.6 W/mK, what is the local heat transfer coefficient in the developed region of the flow? Give your answer in W/m2K to 1 decimal place. I AM POSTIING THIS AGAIN. PLEASE STOP ? COPY FROM INTERNET AND SEND RANDOM SOLUTION. HINT THE FINAL ANSWER IS 38.4 But i need step by step solution. if you don't get this value don't send it please, reject and add the creditarrow_forward
- A shell-and-tube process heater is to be selected to heat water (cp = 4190 J/kg.K) from 20°C to 90°C by steam flowing on the shell side. The heat transfer load of the heater is 600 kW. If the inner diameter of the tubes is 1 cm and the velocity of water is not to exceed 3 m/s, determine how many tubes need to be used in the heat exchanger.arrow_forwardbased on a double-pipe counter flow heat exchanger to be used to cool oil that enters the heat exchanger at 300°F to 105°F at a rate of 5 lbm/s by water that enters at 70°F at a rate of 3 Ibm/s. The diameter of the tube is 1 in. and the length is 20 ft. The measured overall heat transfer coefficient of this heat exchanger is 2.14 Btu/s-ft2-°F. [Oil, c, = 0.525 Btu/lbm°F, Water, c, = 1.0 %3D Btu/lbm°F] The logarithmic mean temperature difference in °C is 46.1 cannot be determined 35.0 59.4arrow_forwardQ14) A 65-kg beef carcass (k-0.47 W/m °C and a-0.13x10-6 m²/s) initially at a uniform temperature of 37°C is to be cooled by refrigerated air at -6°C flowing at a velocity of 1.8 m/s. The average heat transfer coefficient between the carcass and the air is 22 W/m2°C. Treating the carcass as a cylinder of diameter 24 cm and height 1.4 m and disregarding heat transfer from the base and top surfaces, determine how long it will take for the center temperature of the carcass to drop to 4°C. Also, determine if any part of the carcass will freeze during this process. Air -6°C Beef 37°Carrow_forward
- A shell-and-tube heat exchanger is used to cool compressed liquid methanol from 176 °F to 104 °F. The methanol flows on the shell side of the exchanger. The coolant is water that rises in temperature from 50 °F to 86 °F and flows within the tubes at a rate of 68.9 kg s1. Finding the appropriate thermophysical data and applying the proper equations, you are required to do the following: (a) Calculate i) methanol mass flow rate in the exchanger, ii) methanol volumetric flowrate at the inlet of the exchanger. (b) i) For the counter-current flow of the fluids calculate the log temperature difference, ii) explain the purpose of calculating this difference, iii) explain, quantitatively, why is the counter-current flow in heat exchangers preferred to co-current flow. meanarrow_forwardA counter-flow heat exchanger is used to cool water from 60°C to 20°C. The water flows at 0.2 m/s through the inner tube and the cooling fluid flows in the enclosure. The inner tube is 6-cm in diameter and 15-m in length. It is thin and made of copper. The flow rate of the cooling fluid is 1.2 kg/s and convection coefficient is 360 W/m².°C. The specific heat of the cooling fluid is 1600 J/kg. °C. The surface temperature of the inner tube can be approximated as almost isothermal. (a) What is the mass flow rate of water? 0.56 kg/s (b) What is the effectiveness of this heat exchanger? 0.285arrow_forwardA heat exchanger is being used to transfer heat between water and a benzene. The benzene enters the heat exchanger at 1.2 m3/h with a temperature of 90 C. The water enters the heat exchanger at 1 m3/h at a temperature of 15°C. The UA product of the heat exchanger is found to be 2800 kJ/h-°K. . Determine (a) the outlet temperature of water and benzene (b) the heat transfer rate between the fluids for a counter-flow heat exchanger.arrow_forward
- Engr. Dizon, a mechanical engineer, is planning to construct a cooling water pond in Laguna for a power plant. The power plant is known to discharge 20 m/s of cooling water. Estimate the required surface area (in hectares) of the pond if the water temperature is to be lowered from 45 C at its inlet to 35.5 C at its outlet. Assume specific heat of water is 4.186 kJ/kg-K, and an overall heat transfer coefficient of 0.0412 kJ/s-m2-K. Round off your answer to the nearest whole number.arrow_forwardA food factory uses hot water to wash and clean foods. The drained water, which has a mass flow rate of 12 kg/min, still have a temperature of 45°C. consider a concept design solution of waste heat recovery for pre-heating fresh water, which has an inlet temperature of 15°C and mass flow rate of 8 kg/min. A clear justification should be included.arrow_forwardA long counter-flow heat exchanger cools water from 40°C to 10°C by passing the water via the inner tube through an enclosure of cold fluid. The water is flowing through a 3-cm diameter tube at a rate of 0.27 kg/s. The cold fluid enters the enclosure at −10°C and has a convection coefficient of 1200 W/m².K. The mass flow rate of the cold fluid and its specific heat are 1.2 kg/s and 1340 J/kg-K, respectively. (a) Assuming the flow is fully developed, find out the convection coefficient of the water flow. (b) What is the length of the heat exchanger? 1554 W/m²K 2 21.9m Water Cold Fluidarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY