Two identical pulses each of magnitude 12 V and width 2 us are incident at i = 0 on a lossless transmission line of length 400 m terminated with a load. If the two pulses are separated 3 us and u = 2 x 10° m/s, Find time required by pulse to reach from generator to load end.
Q: In a laboratory, we found that the static wavelength ratio was 2.0 as a result of an experiment…
A: Given :Z0 of T.L =50 ohm Standing wave ratio (s)=2.0The distance between succesive voltage minimum…
Q: At an operating frequency of 300 MHz, a lossless 50-2 air-spaced transmission line 2.5 m in length…
A: Thank you for posting the question at Bartleby according to our guidelines we solve one question at…
Q: The 50 ohm half wavelength lossless transmission line is terminated with a 60 ohm load impedance. If…
A:
Q: The following lossless network excited with the microwave source having f = 9 GHZ. if Zo=74 Q, 6,…
A: For lossless transmission line Characteristic Impedance is Zo Zo =√(L/C) Zo^2 = L/C L =…
Q: [3] which produces a voltage reflection coefficient Fx = 0.52 angle -320 at a point X on the line…
A: A transmission line with no line resistance and no dielectric loss is known as a lossless line. This…
Q: A 50-N lossless line is terminated in Z, = 40 – j30 N. Determine the following: (a) the reflection…
A: A 50Ω lossless line is terminated in Z1=40-j30Ω. Now, to determine the reflection coefficient at the…
Q: 10. A lossless coaxial cable terminates cuit load. What is the transmission line voltage expressed…
A: Coaxial Cable- They are special type of cables which have a conductor in the middle and protected by…
Q: A 30-m-long lossless transmission line with Z, = 50 2 operating at 2 MHz is terminated with a load…
A:
Q: An air lossless transmission line is operating at frequency of 3 MHz and has a length of 1.75 A,…
A: As per our company guidelines we are supposed to answer only first 3 subpart kindly repost other…
Q: A load with an impedance of 424.3045° N is connected to a 100 N lossless line. Using the Smith Chart…
A:
Q: 4 GHz signals propagate along a parallel plate transmission line. The line has width 5 mm, height 10…
A: Note: We are authorized to answer three subparts at a time since you have not mentioned which part…
Q: Q / Consider a cellular system with 500 total allocated voice channel frequencies. Calculate the…
A: Cellular System, Total number of voice channel=500 calculate S/I ratio is equal to 4,7,12; N=4,7,12
Q: 10. A slotted line is used to measure VSWR of the load at 2 GHz by double minima method. If the…
A: Given f = 2GHz d2-d1 = 0.5 cm
Q: 1) Transmission line properties of typical high-speed interconnects are experimentally investigated…
A: Given parameters phase constant β=200rad/mattenuation constantα =140NP/mcharacteristic impedance…
Q: In a lossless medium for which 7 = 607, µ, = 1, and H = -0.1 cos (wt - z) a, 0.5 sin (wt - z)a, A/m,…
A: The wave is function of space and time. The EM wave is formed when electric field is in contact with…
Q: A three phase 60HZ, 85kV transmission line consisting of 3 conductors are placed at the corners of a…
A: As per Bartleby guidelines we are allowed to solve only three subparts, please ask the rest again.
Q: The following characteristics have been measured on a lossy transmission line at 100 MHz: Zo = 50 +…
A:
Q: The lossless network given below is excited with a microwave source having frequency f={frq_q1} GHz.…
A: Reflection coefficient
Q: In a lossless medium for which 7 = 607, µ, = 1, and H = -0.1 0.5 sin (wr - z)a, A/m, calculate e, w,…
A: The solution can be achieved as follows.
Q: Derive an expression for sag in a transmission line of equal height poles
A: Consider the diagram for the transmission line between two supports of of equal height as point A…
Q: The capacitance per unit length and the characteristic impedance of a lossless Transmission line are…
A: It is given that, the capacitance per unit length and the characteristic impedance of a lossless…
Q: A piece of RG-59B/U Coaxial cable has a nominal capacitance of 0.4 F/m, and 7.5 H inductance per…
A:
Q: A loss-less 200N line is terminated on a load given by (200-j200)№. Given that the propagation…
A: the Given loss-less 200Ω line is terminated on a load 200-j200Ω The Propagation constant is…
Q: A 5.2cm long, lossless 100Ω transmission line was terminated with a load of ?? = 30 + 50Ω. With the…
A: The load reflection coefficient is: So, the magnitude of the reflection coefficient is: 0.617 And,…
Q: A 3-phase, 60 Hz, 600 kV, lossless transmission line is 600 km long. The line inductance is 2…
A: Given- VL-L=600 kVf = 60 HzL = 2 mH/km/phaseC = 20 nF/km/phase To Find- Phase constant Surge…
Q: A 376-2 lossless air transmission line is connected to a complex load composed of a 749-2 resistor…
A:
Q: A lossless 500 transmission line was terminated with a load of = 17.7 + j11.80. The length of the…
A: we need to calculate the reflection coefficient at the entrance.
Q: A lossless air-filled transmission line with Z0 = 50Ω is terminated in a load with ZL = (150 - j100)…
A: Lossless air-filled transmission line with Zo=50Ω is terminated withZL=150-j100Ω.Reflection…
Q: A piece of RG-59B/U Coaxial cable has a nominal capacitance of 0.4F/m, and 7.5 H inductance per…
A: It is given that: Nominal capacitance= C=0.4 F/mInductance per meter=L=7.5 H/mDiameter of inner…
Q: Which transmission medium is ideal for the most densely inhabited areas? Discuss
A: Transmission medium- Transmission Media are the communication channels through which data is…
Q: Problem #5) An 80cm long, lossy transmission line has the following characteristics: Z = 752, Y =…
A: An 80 cm long, lossy transmission line has the following characteristics: Zo=75 Ω, γ=0.10+j2.876 The…
Q: -ohm resistive load and is operated at 100 MHz. At an electrical length of 0.4 wavelengths, what is…
A:
Q: A 30-m-long lossless transmission line with Z, = 50 N operating at 2 MHz is terminated with a load…
A:
Q: In a laboratory, we found that the static wavelength ratio was 2.0 as a result of an experiment…
A: Given :Zo= 50 ohm Standing wave ratio=2.0 The distance between successive voltage minima of 25 cm…
Q: A 90 N lossless line is 0.6A long, If S = 1.9 and 6, = -68°, use the Smith chart to find the load…
A:
Q: A 50Ω lossless transmission line is terminated in a load (50+j100) Ω. Using a smith chart, determine…
A: Given, Impedance, Z0=50ΩLoad Impedance, ZL =(50+j100)Ω
Q: A 300ᘯ transmission line is 0.8 m long and terminated with a short circuit. The line is operating in…
A: A 300ᘯ transmission line is 0.8 m long and terminated with ashort circuit.The line is operating in…
Q: 6. The standing-wave ratio on a lossless 300-2 transmission line terminated in an unknown ZL is S=…
A:
Q: Q3: A lossy transmission line has a complex propagation constant of y 0.012+5.8 (/m). If the voltage…
A: Given,Y=0.012+j5.8 /mV0=12Voltz=d=12 mWe know that,V=V0e-αz Equation 1where α is…
Q: 20-km fiber optic cable whose attenuation per unit length is equal to 1 dB/km connects the…
A: A fiber optic cable that contains one or more optical fibers is used to carry light. Length of the…
Q: An extra high voltage transmission line of length 300 km can be approximated by a lossless line…
A: Given, An extra high voltage transmission line of length, l = 300 km Propgation constant, β=…
Q: Question 3 (a) A lossless transmission line with Z. line is terminated with a load impedance, Z, =…
A:
Q: A 75 Q lossless transmission line is to be matched with a 100-j802 load using Single stub. Calculate…
A: Given :Z0=75 ΩZL=100-j80 ΩZL=128.06∠38.66° f=30 MHz
Q: A material with &r = 2.25 is used as the insulating material in a lossless coaxial line with…
A: “Since you have asked multiple questions, we will solve the first question for you. If you want any…
Q: Homework 1 1. The following table lists a set of empirical path loss measurements. Assume a carrier…
A: Given: The following table lists a set of empirical path loss measurements. Assume a carrier…
Q: [Q6] Determine the primary constants, R, L, G, and C for a distortion-less line working at 300 MHz.…
A:
Q: The distance from the load to the source moving on a lossless transmission line is 2.5 revolutions…
A: The transmission lines are used for power transmission from one place to another. The power system…
Step by step
Solved in 2 steps
- Why the Capacitance effect is neglected in Short Transmission Line.g) Why the Capacitance effect is neglected in Short Transmission Line.A single-phase transmission line consisting of two conductors, the radius of each conductor is 0.4 cm, the distance between the conductors is three and half meters and the height above ground is eight meter. Determine 1)The capacitance in uF/km without effect of ground 2)The capacitance in uF/km with effect of ground
- A double-circuit its capacitance to neutral per mile. line is shown below. The conductor radius is 0.0452 ft. Determine 16' 16' a b 22' c' b' a'The affect of the earth plane is to slightly increase the capacitance, and as the line height increases, the effect of earth becomes negligible. True False5. Two cascaded lossless transmission lines are terminated by Z₁-2502, as shown below.. a) Calculate the reflection coefficient and the standing wave ratio at the load, i.e., the CC' terminal. b) Determine the characteristic impedance of the quarter-wavelength transformer, Zol, to match the cascaded line to a 6492 generator. B A- A'. Zol 11= 2/4 B' Zo2=75 92 12=32/4 C C ZL=2592
- For the Figure 8 shown: A 494 -km long, 48 Hz, three-phase, transmission line is composed 2 parallel lines. The conductors in the lines are stranded with GMR of 12.06 -mm each. If the distance D in the figure is 2.83 m., What is inductance per line in (mH)? Figure 8 'o ✪ 1.732D 1.732D b' D 1.732D 2D D 1.732D 。 a19- Noise due to inductive coupling can be reduced by twisting the wires carrying a signal. True False4/ Which parameter is neglected or ignored in Short Transmission Lines? A. SHUNT CAPACITANCE ONLY B. SERIES CONDUCTANCE AND SHUNT CAPACITANCE C. SHUNT CONDUCTANCE AND SHUNT CAPACITANCE D. SHUNT CONDUCTANCE ONLY
- One circuit of a single-phase transmission line is composed of three solid 0.12" radius wires. The return circuit is composed of two 0.15" radius wires. Find the inductance of the complete line in mH/mi. The distance between wires are 40" horizontally and 25" vertically. A. 2.54 mH/mi B. 2.478 mH/mi C. 2.488 mH/mi D. 2.567 mH/mi Provide Clear ExplainationFor the Figure 8 shown: A 181 -mile long, 60 Hz, three-phase, transmission line is composed 2 parallel lines. The conductors in the lines are stranded with GMR of 0.3146 -inch each. If the distance D in the figure is 6 ft., What is inductance per line in (mH)? Figure 8 o ‘O 1.732D 1.732D b' D 1.732D 2D D 1.732D 。2. A transmission line with Zo = 1000 and 1 = 0.42 is terminated with a Z₁ = 30+ j500 load. The internal impedance of generator is Zg. a) Find reflection coefficient at the load and SWR on the line by using Smith Chart. b) To be maximum power transfer to load, find the Zg value and maximum power Pmax