Three-bus system network consists of TWO generators located at buses 1 and 2 and TWO loads located at buses 2 and 3. The magnitude of voltage at bus 1 is maintained at 1.05 per unit, while at bus 2, the voltage magnitude is set to 1.03 per unit with real power generation is set to 2.0 per unit. The scheduled load at buses 2 and 3 are 50+j 20 MVA and 60 + j25 MVA, respectively. Line admittances are tabulated in Table 1. Calculate the voltage magnitude and phase values at bus 3, and phase value of voltage at bus 2 using Newton-Raphson method for ONE (1) iteration only.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter12: Power System Controls
Section: Chapter Questions
Problem 12.13P
icon
Related questions
icon
Concept explainers
Question
Three-bus system network consists of TWO generators located at buses 1 and 2 and TWO
loads located at buses 2 and 3. The magnitude of voltage at bus 1 is maintained at 1.05 per
unit, while at bus 2, the voltage magnitude is set to 1.03 per unit with real power generation is
set to 2.0 per unit. The scheduled load at buses 2 and 3 are 50+j 20 MVA and 60+j25 MVA,
respectively. Line admittances are tabulated in Table 1. Calculate the voltage magnitude and
phase values at bus 3, and phase value of voltage at bus 2 using Newton-Raphson method for
ONE (1) iteration only.
From line
1
1
2
To line
2
3
3
Table 1
G
1.25
5
1.67
B
-3.75
-15
-5
Transcribed Image Text:Three-bus system network consists of TWO generators located at buses 1 and 2 and TWO loads located at buses 2 and 3. The magnitude of voltage at bus 1 is maintained at 1.05 per unit, while at bus 2, the voltage magnitude is set to 1.03 per unit with real power generation is set to 2.0 per unit. The scheduled load at buses 2 and 3 are 50+j 20 MVA and 60+j25 MVA, respectively. Line admittances are tabulated in Table 1. Calculate the voltage magnitude and phase values at bus 3, and phase value of voltage at bus 2 using Newton-Raphson method for ONE (1) iteration only. From line 1 1 2 To line 2 3 3 Table 1 G 1.25 5 1.67 B -3.75 -15 -5
Expert Solution
steps

Step by step

Solved in 5 steps

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning