Q1. A certain power station has the following daily load cycle:- Time (6-8)am (8-12)am (12-16)pm (16-20)pm (20-24)pm (24-6)am In hours Load in MW 20 40 60 20 50 20 The daily Load being served by a run - of - river as a base station and a steam as a peak load station, rated of each one is 35MW. The ratio of number of units supplied by these stations is as follows: Steam station: run - of - river station : 6: 4. Draw load duration curve then determine i. Units generated per day by each station. ii. Maximum demand by each station. iii. Utilization factor by each station.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.16P: A single-phase, 120V(rms),60Hz source supplies power to a series R-L circuit consisting of R=10 and...
icon
Related questions
Question
Q1. A certain power station has the following daily load cycle:-
Time
(6-8)am
(8-12)am (12-16)pm (16-20)pm (20-24)pm
(24-6)am
In hours
Load in MW
20
40
60
20
50
20
a run
The daily Load being served by a run - of - river as a base station and a steam as a peak load
station, rated of each one is 35MW. The ratio of number of units supplied by these stations
is as follows: Steam station: run - of - river station : 6: 4.
Draw load duration curve then determine
i. Units generated per day by each station.
ii. Maximum demand by each station.
iii. Utilization factor by each station.
Transcribed Image Text:Q1. A certain power station has the following daily load cycle:- Time (6-8)am (8-12)am (12-16)pm (16-20)pm (20-24)pm (24-6)am In hours Load in MW 20 40 60 20 50 20 a run The daily Load being served by a run - of - river as a base station and a steam as a peak load station, rated of each one is 35MW. The ratio of number of units supplied by these stations is as follows: Steam station: run - of - river station : 6: 4. Draw load duration curve then determine i. Units generated per day by each station. ii. Maximum demand by each station. iii. Utilization factor by each station.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Maximum power transfer theorem
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning