Problem 2 - R-134a commercial refrigerator with a water cooled condenser A commercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerated space at -35°C by rejecting waste heat to cooling water that enters the condenser at 18°C at a rate of 0.25 kg/s and leaves at 26°C. The refrigerant enters the condenser at 1.2 MPa and 50°C and leaves at the same pressure subcooled by 5°C. If the compressor consumes 3.3 kW of power, determine: The mass flow rate of the refrigerant. The refrigeration load (heat rate removed from the cold space). The COP of this refrigerator. The minimum power input to the compressor for the same refrigeration load. Hint: Carnot refrigerator.

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
Problem 2- R-134a commercial refrigerator with a water cooled condenser
A commercial refrigerator with refrigerant-134a as the working fluid is used to keep the
refrigerated space at -35°C by rejecting waste heat to cooling water that enters the condenser
at 18°C at a rate of 0.25 kg/s and leaves at 26°C. The refrigerant enters the condenser at 1.2
MPa and 50°C and leaves at the same pressure subcooled by 5°C. If the compressor consumes
3.3 kW of power, determine:
The mass flow rate of the refrigerant.
The refrigeration load (heat rate removed from the cold space).
The COP of this refrigerator.
The minimum power input to the compressor for the same refrigeration load. Hint:
Carnot refrigerator.
26°C
1.2 MPa
5°C subcooled
fo
Expansion
valve
Condenser
Evaporator
Q₁
Water
18°C
1.2 MPa
50°C
Compressor
Win
Transcribed Image Text:Problem 2- R-134a commercial refrigerator with a water cooled condenser A commercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerated space at -35°C by rejecting waste heat to cooling water that enters the condenser at 18°C at a rate of 0.25 kg/s and leaves at 26°C. The refrigerant enters the condenser at 1.2 MPa and 50°C and leaves at the same pressure subcooled by 5°C. If the compressor consumes 3.3 kW of power, determine: The mass flow rate of the refrigerant. The refrigeration load (heat rate removed from the cold space). The COP of this refrigerator. The minimum power input to the compressor for the same refrigeration load. Hint: Carnot refrigerator. 26°C 1.2 MPa 5°C subcooled fo Expansion valve Condenser Evaporator Q₁ Water 18°C 1.2 MPa 50°C Compressor Win
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 5 steps with 4 images

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The