(b) Figure Q2 shows a power system network. The generators at Bus 1 and Bus 2 are represented by their equivalent current sources with the reactance in per unit on a 100MVA base. The lines are represented by n model where the series and shunt reactances are expressed in per unit on a 100MVA base as well. However, the load located at Bus 3 and Bus 4 are expressed in MW and MVar. (i) Reconstruct the network impedance shown in the figure into the network admittance by assuming the voltage magnitude at Bus 3 and Bus 4 are 1.0 per unit, respectively. (ii) Calculate the bus admittance matrix of the system.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.26P: A bank of three single-phase transformers, each rated 30MVA,38.1/3.81kV, are connected in Y- with a...
icon
Related questions
icon
Concept explainers
Question
(b) Figure Q2 shows a power system network. The generators at Bus 1 and Bus 2
are represented by their equivalent current sources with the reactance in per unit
on a 100MVA base. The lines are represented by n model where the series and
shunt reactances are expressed in per unit on a 100MVA base as well. However,
the load located at Bus 3 and Bus 4 are expressed in MW and MVar.
Reconstruct the network impedance shown in the figure into the network
admittance by assuming the voltage magnitude at Bus 3 and Bus 4 are 1.0
per unit, respectively.
(i)
(11)
Calculate the bus admittance matrix of the system.
Transcribed Image Text:(b) Figure Q2 shows a power system network. The generators at Bus 1 and Bus 2 are represented by their equivalent current sources with the reactance in per unit on a 100MVA base. The lines are represented by n model where the series and shunt reactances are expressed in per unit on a 100MVA base as well. However, the load located at Bus 3 and Bus 4 are expressed in MW and MVar. Reconstruct the network impedance shown in the figure into the network admittance by assuming the voltage magnitude at Bus 3 and Bus 4 are 1.0 per unit, respectively. (i) (11) Calculate the bus admittance matrix of the system.
j0.2
j0.2
j0.25
-j4
j0.18
j0.14
j0.25
S3=120+/35MVA
S=180+/45MVA
Figure Q2
Transcribed Image Text:j0.2 j0.2 j0.25 -j4 j0.18 j0.14 j0.25 S3=120+/35MVA S=180+/45MVA Figure Q2
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Types of Distribution in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning