An RTD with a=0.003/°C and R=300 Q at 25 °C will be used to measure the temperature of hot gas flowing in a pipe. The disspation constant is 25 mW/°C, and the time constant is 5.5 s. Normal gas temperature is in the range of 100 °C to 220 °C. You are required to design a system by which the temperature variation is converted into a voltage of -2.0 to +2.0 V. Keep self-heating to 0.5 °C. Occasionally a turbulent shock wave will propagate down the pipe, causing a sudden reduction to less than 50 °C. Device a comparator alarm that will signal such an event within 3s of dropping below 100 °C. Answer the following questions: 1. The RTD resistance at 100 °C and 220 °C is: O a. 221.25 Q and 504.75 Srespectively Ob. 378.75 Q and 504.75 2 respectively O c. 378.75 Q and 95.25 Q respectively O d. 221.25 Q and 95.25 2 respectively

EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN:9781337516549
Author:Simmons
Publisher:Simmons
Chapter19: Special-purpose Outlets-water Pump, Water Heater
Section19.2: Water Heater Branch Circuit
Problem 8R: For residential water heaters, the Consumer Product Safety Commission suggests a maximum temperature...
icon
Related questions
Question
An RTD with a=0.003/°C and R=300 2 at 25 °C will be used to measure the temperature of hot gas flowing in a pipe. The disspation constant is
25 mW/°C, and the time constant is 5.5 s. Normal gas temperature is in the range of 100 °C to 220 °C. You are required to design a system by
which the temperature variation is converted into a voltage of -2.0 to +2.0 V. Keep self-heating to 0.5 °C. Occasionally a turbulent shock wave
will propagate down the pipe, causing a sudden reduction to less than 50 °C. Device a comparator alarm that will signal such an event within 3s
of dropping below 100 °C. Answer the following questions:
1. The RTD resistance at 100 °C and 220 °C is:
O a.
221.25 Q and 504.75 2 respectively
O b. 378.75 and 504.75 Q respectively
O c.
378.75 2 and 95.25 2 respectively
O d. 221.25 Q and 95.25 Qrespectively
Transcribed Image Text:An RTD with a=0.003/°C and R=300 2 at 25 °C will be used to measure the temperature of hot gas flowing in a pipe. The disspation constant is 25 mW/°C, and the time constant is 5.5 s. Normal gas temperature is in the range of 100 °C to 220 °C. You are required to design a system by which the temperature variation is converted into a voltage of -2.0 to +2.0 V. Keep self-heating to 0.5 °C. Occasionally a turbulent shock wave will propagate down the pipe, causing a sudden reduction to less than 50 °C. Device a comparator alarm that will signal such an event within 3s of dropping below 100 °C. Answer the following questions: 1. The RTD resistance at 100 °C and 220 °C is: O a. 221.25 Q and 504.75 2 respectively O b. 378.75 and 504.75 Q respectively O c. 378.75 2 and 95.25 2 respectively O d. 221.25 Q and 95.25 Qrespectively
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Thermocouple
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
EBK ELECTRICAL WIRING RESIDENTIAL
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT