Question
Chapter 36, Problem 7SQ
To determine
Explain why the starting cycle can persist for a long time with an increase in the motor load.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
1- What is the starting torque developed by a split-phase or a capacitor start
motor?
2- What is the current in-rush at the time of starting the motor? Does it cause
severe fluctuations on the line?
4.a. The device which responds to the heat developed within the motor is theA. shading coil.B. short-circuiter.C. bimetallic protector.D. current-operated relay.4.b. How is a rotating magnetic field produced during starting in a split-phase motor?A. A capacitor is inserted in the auxiliary-winding circuit.B. A low resistance coil is placed around a portion of each pole.C. Brushes are shifted off the hard-neutral position.D. An auxiliary winding is made with a high ratio of resistance to reactance.
1.The other possible methods of starting 3-phase induction motors. 2.How it was made sure in the control circuit that star and deltacontactors cannot operate simultaneously?3. Why we do not have the motor continue running in its star connection. 4. What is the relationship between star and delta currents?
Chapter 36 Solutions
Electric Motor Control
Ch. 36 - Are the secondary resistors connected in three...Ch. 36 - Do secondary resistors on starters with three or...Ch. 36 - Does reversing the secondary rotor leads mean that...Ch. 36 - If one of the secondary resistor contacts (S2)...Ch. 36 - In Figure 362, how many different interlocking...Ch. 36 - Referring to Figure 364, why is it not possible to...Ch. 36 - Prob. 7SQCh. 36 - If there is a locked rotor in the secondary...Ch. 36 - Why is it necessary to remove the jumpers in...Ch. 36 - Prob. 10SQ
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- What is the reason why a synchronous motor can be found running at no load?arrow_forward(B)- Indicate whether the following statements are true or false and correct the false statements 1- Wave wound armature has two parallel paths. 2- The current ratio is equal to 1/ turn ratio at no-load while the voltage ratio is equal to 1/ turn ratio at full load 5.4. 3-When a series de motor is operated without a load, the armature draws excessive current Ph 4- The hysteresis loss can be minimized by using core of thin laminations ل لهول 259 Ne 02arrow_forward1. Explain the working Principle of Single Phase Induction Motor. 2. What are the different types of Starters to control AC-Motor. Explain briefly. 3. Explain DOL starter of Single Phase Induction Motor briefly. 4. What is the purpose of the magnetic contactor? 5. What is the use of auxiliary contact in the magnetic controller? 6. What happens when the holding coil gets the supply in the magnetic controller? 7. Explain the working principle of a relay.arrow_forward
- A. The DC motor in Figure 3 on Worksheet 8 is aa) cumulatively connected short-shunt compound DC motor b) cumulatively connected long-shunt compound DC motor c) differentially connected short-shunt compound DC motor d) shunt DC motorB. Is the DC motor in Figure 1 on Worksheet 8 turning in the same direction as that in Figure 3?a) yes b) noarrow_forward12 Why does DC motor sometimes run too fast when under-loaded? * Due to high line voltage O all of the above Due to armature reaction O Due to weak field Due to brush-shifted to neutralarrow_forwardOverhauling is a condition in which the motor’s armature rotates ( ] than the rotating stator field. A) more slowley B) more rapidlyarrow_forward
- You are working as a plant electrician. You are told that a large DC motor was returned from the rewind shop and was installed on the previous shift. The motor seemed to operate properly until load was added. The motor then stopped, reversed direction, and began to run at high speed. What is the probable cause of the trouble, and what would you do to correct the problem? Explain your answer.arrow_forwardWhy induction motor cannot run on synchronous speed? Explain using slip.arrow_forwardExplain how does the current will be reduced during the starting of the motor.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Electricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage LearningDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage Learning
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
FMPR-103 pt1 l Power Systems Protection v1; Author: L&D for Protection and Control;https://www.youtube.com/watch?v=ELWncjsh5uE;License: Standard Youtube License