Question
Chapter 51, Problem 1SQ
To determine
Explain why the three phase braking reduces motor heating when compared with single phase breaking.
Expert Solution & Answer
Explanation of Solution
Discussion:
A DC dynamic brake is a single phase braking used in various induction motors. It requires more current to achieve the braking torque. Therefore, the heat dissipation is more in single phase braking. In a three phase braking, the motor requires less current for the same braking torque, so that the motor heating reduces. Due to the additional winding in a three phase braking motors, the ampere turns are gained.
Conclusion:
Thus, the reason for the reduction of motor heat in three phase braking is explained.
Want to see more full solutions like this?
Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
Write short note on rheostatic braking and plugging braking
What are the advantages and disadvantages of the plugging braking?
In plugging type of braking system of DC motor, the current in the series and shunt fields must not be reversed"
True
False
Chapter 51 Solutions
Electric Motor Control
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Inductive reactance, resistance, and impedance are always present in circuit serving motors. Which of the three actually determines the required conductor size?arrow_forwardWhat is plugging type braking?arrow_forwardFor what purpose is the short circuit test performed in asynchronous motor? Please explain.arrow_forward
- 1-) a) Does the slip increase as the load increases in an asynchronous motor? Explain what is the reason for this. b) What does it mean when the slip is 0, 1, -1 in asynchronous motor, how is it achieved? Explain.arrow_forwardExplain regenerative braking in detail , as applied to electric locomotivesarrow_forwarda) Does the slip increase as the load increases in an asynchronous motor? What is the reason of this? b) What does it mean for Slip 0, 1, -1 in asynchronous motor, how is it achieved? Explain.arrow_forward
- 3. Why integral wind-up is harmful in a closed-loop system? Explain.arrow_forwardExplain why volatge is decreased for resistive and inductive loading for a synchronous motor?arrow_forwardYour only control over the load voltage is the adjustment of a variable resistance in parallel with the load, what does this imply about the APU’s output voltage (directly across the generator terminals), compared to the target load voltage?arrow_forward
- Depending on their power factor ratings, what is the range of the leading power factor at which synchronous motors operate?arrow_forwardHow does grid synchronization work in a multi-generator power system?arrow_forwardWhich of the following factor is responsible for negative voltage regulation of a DC generator? Under compunding Over compounding Flat compounding Critical resistancearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Electricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning