Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN: 9781305578296
Author: John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 43, Problem 8RQ
Which metering device is most efficient in heat pumps?
A. A thermostatic expansion valve
B. An automatic expansion valve
C. A capillary tube
D. An orifice or restrictor
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Which metering device is most efficient in heat pumps?A. A thermostatic expansion valveB. An automatic expansion valveC. A capillary tubeD. An orifice or restrictor
7)
What are the components of a pumping system?
Chapter 43 Solutions
Refrigeration and Air Conditioning Technology (MindTap Course List)
Ch. 43 - How does a heart pump resemble a refrigeration...Ch. 43 - Name the three common sources of heat for heat...Ch. 43 - What large line connects the indoor unit to the...Ch. 43 - Why is the indoor unit not called an evaporator?Ch. 43 - When is the outdoor unit called an evaporator? A....Ch. 43 - The indoor coil is called a condenser during...Ch. 43 - Why is it important to have drainage for the...Ch. 43 - Which metering device is most efficient in heat...Ch. 43 - Where is the only permanent suction line on a heat...Ch. 43 - What type of drier may be used in the liquid line...
Ch. 43 - Where must a suction-line drier be placed in a...Ch. 43 - What controls the heat pump to determine whether...Ch. 43 - Can a heat pump switch from heating to cooling and...Ch. 43 - What must be done when frost and ice build up on...Ch. 43 - True or False: All heat pumps are practical...Ch. 43 - Why are scroll compressors more efficient than...Ch. 43 - Describe why variable-speed compressor motors are...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- An automatic expansion valve system responds to an overcharge of refrigerant by A. low suction pressure. B. high head pressure. C. a flooded compressor. D. both B and Carrow_forwardWhen evacuating a refrigeration system that has solenoid valves, what special procedure must be followed?arrow_forwardWhich of the following statements is not true about orifice tube systems? The suction line must be cool to the touch from the evaporator outlet to the compressor. The liquid line from the condenser outlet to the evaporator inlet should be cool. The evaporator should feel very cold. The accumulator must be cool to the touch.arrow_forward
- The capillary tube metering device is usually fastened to the______for heat exchange. A. suction line B. compressor discharge line C. liquid linearrow_forwardWhy is a circulating brine system more attractive for ship refrigeration than individual evaporators?arrow_forwardQuality means _________ when referring to a refrigerant.arrow_forward
- Where must a suction-line drier be placed in a heat pump after a motor burnout?arrow_forwardChoose correct answer: The purpose of a capillary tube in a refrigeration system is to ___________ A. Reduce the pressure and not temperature B. Reduce the temperature and pressure C. Increase the temperature and pressure D. Reduce the temperature and not pressurearrow_forwardThe installation of a 31⁄2-ton central air-conditioning system needs thefollowing:1 compressor, condenser, and evaporator . . . . . . $1,142.001 concrete slab for condenser . . . . . . . . . . . . . . . $32.0021⁄2 pounds refrigerant R-134a charge . . . . . . . . . $1.20 per pound2 foot drainpipe (1-inch diameter) . . . . . . . . . . . . . $0.42 per foot30 foot connecting tubing . . . . . . . . . . . . . . . . . . . $0.79 per foot1 plenum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $47.501 roll duct insulation . . . . . . . . . . . . . . . . . . . . . . . $52.951 roll duct tape . . . . . . . . . . . . . . . . . . . . . . . . . . . $2.491 thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . $28.9535 foot thermostat wire . . . . . . . . . . . . . . . . . . . . . $5.95Labor (3 installers—8 hours each) . . . . . . . . . . . . $12.75 per hourarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningAutomotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Mod-01 Lec-16 Basics of Instrumentation; Author: nptelhrd;https://www.youtube.com/watch?v=qbKnW42ZM5c;License: Standard YouTube License, CC-BY