Question
Chapter 4, Problem 37R
To determine
Fill in the blanks with the appropriate sentence.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
2.a. What's defined as an assembly consisting of a service raceway, guy wires or braces, service head, andany fittings necessary for the termination and support of overhead service conductors?A. Drip loopB. Service lateralC. Service dropD. Service mast
2.b. What's likely to happen when connected parallel conductors are different lengths?A. An NEC violationB. Misidentification of conductor cablesC. An uneven distribution of currentD. Conductor termination
Enumerate and discuss the standard criteria to be considered when designing overhead pole lines to minimize the visual impact of the line to the public.
Some electricians do not bother to calculate the minimum size of neutral service conductor. They size the minimum ungrounded conductor size and then use this information to determine the minimum neutral conductor size. Explain how they determine the minimum neutral size using the minimum ungrounded conductor siz
Chapter 4 Solutions
Electrical Wiring Residential
Ch. 4 - The largest size solid conductor generally...Ch. 4 - What is the minimum branch-circuit wire size that...Ch. 4 - What exceptions, if any, are there to the answer...Ch. 4 - What determines the ampacity of a wire?Ch. 4 - What unit of measurement is used for the diameter...Ch. 4 - What unit of measurement is used for the...Ch. 4 - What is the voltage rating of the conductors in...Ch. 4 - Indicate the allowable ampacity of the following...Ch. 4 - Prob. 9RCh. 4 - What are the colors of the conductors in...
Ch. 4 - For nonmetallic-sheathed cable, may the...Ch. 4 - Prob. 12RCh. 4 - Under what condition may nonmetallic-sheathed...Ch. 4 - a. What is the maximum distance permitted between...Ch. 4 - Prob. 15RCh. 4 - Prob. 16RCh. 4 - Prob. 17RCh. 4 - Prob. 18RCh. 4 - Prob. 19RCh. 4 - Circle the correct answer to the following...Ch. 4 - When running Type NM cable through a bored hole in...Ch. 4 - Where is the main service-entrance panel located...Ch. 4 - Is it permitted to use flexible metal conduit over...Ch. 4 - Liquidtight flexible metal conduit may serve as a...Ch. 4 - It is permissible for an electrician to connect...Ch. 4 - Terminals of switches and receptacles marked...Ch. 4 - Wire connectors marked AL/CU are suitable for use...Ch. 4 - A wire connector bearing no marking or reference...Ch. 4 - When Type NM cable is run through a floor, it must...Ch. 4 - When nonmetallic-sheathed cables are bunched or...Ch. 4 - In diagrams A and B, nonmetallic-sheathed cable is...Ch. 4 - The marking on the outer jacket of a...Ch. 4 - A 120-volt branch circuit supplies a resistive...Ch. 4 - In problem 35, it is desired to keep the voltage...Ch. 4 - Prob. 37RCh. 4 - The allowable ampacity of a 4 AWG THHN from Table...Ch. 4 - If, because of some obstruction in a wall space,...Ch. 4 - The recessed fluorescent luminaires installed in...Ch. 4 - Prob. 41RCh. 4 - What size overcurrent device protects the...Ch. 4 - May the 20-ampere small-appliance branch circuits...Ch. 4 - A 30-ampere branch circuit is installed for an...Ch. 4 - In many areas, metal framing members are being...Ch. 4 - Are set screwtype connectors permitted to be used...Ch. 4 - Most armored cable today has 90C conductors. What...Ch. 4 - If you saw two different types of SE cables, how...Ch. 4 - Circle the correct answer defining the type of...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Count the neutral conductor of a 4-wire, 3-phase, wye-connected circuit when the major portion of the load is electric discharge lighting (fluorescent, mercury vapor, high-pressure sodium, etc.), data processing, and other loads where the neutral conductor carries a. grounding b. traveler C. d. current. third harmonic unbalanced conductors to overheat but often overlooked is the possibility ofarrow_forwardQUESTION 3 The power system network is shown in Figure 3. The magnitude of voltage at bus 1 is adjusted to 12 0° per unit, buses 2 and 3 are the load buses. Line impedances are marked in per-unit on 100 MVA base and the charging susceptances are neglected. Determine the bus voltage at load 2 and 3 using the Gauss-Seidel iteration method (accurate to four decimal places). Perform calculation for two iterations. jo.033 P= 400 Mw HQu= 320 MVar Vi = 120° Figure 3 10.05 +P= 300 MW 70.0125 +QF 270 MVararrow_forwardOvercurrent devices are generally not permitted on the ____ conductor. a. ungroundedb. phasec. groundedd. dual-ratedarrow_forward
- write down the factors considered for selection of conductor for overhead LT distribution line. briefly in 65 wordsarrow_forwardThe active component of line current in figure 1 is______. a. 12A b. 20A c. 12A d. 4Aarrow_forward2. What's the primary instrument for locating a break in a cable during emergency maintenance?A. OSAB. OTDRC. MultimeterD. Power meterarrow_forward
- 1.A. When a grounding electrode conductor is connected to the grounded conductor within a serviceequipment enclosure, it's required to be connected to the _______ terminal bus.A. service bonding jumperB. equipment groundingC. grounded conductorD. main bonding jumper1.B. The grounding electrode conductor for a DC system will have that conductor sized no smaller than_______ AWG aluminum.A. 8B. 6C. 10D. 121.C. What are the two key aspects of the installation of the grounding electrode conductor?A. Sizing and protectionB. Bonding and accessibilityC. Materials and placementD. Location and safetyarrow_forwardViva Questions:1. What is the difference between Shunt and Series Stub?2. The stub is used to produce pure resistance at the point of connection (True / False)3. The stub length can be varied from __________________.4. What are the design parameters for stubs?5. Can the stubs be made open or short?arrow_forwardA three-phase double circuit line is composed of ACSR Drake conductors arranged as shown. Calculate: (a) the line-to-neutral capacitance per mile, (b) the line-to-neutral capacitive reactance per mile, (c) the per phase inductance per mile, and (d) the per phase inductive reactance per mile. - 18' 10' 21' 10' 18'arrow_forward
- A? Conductor is defined in NEC 240.2 as a conductor, other than a service conductor, having overcurrent protection ahead of its point of supply that exceeds the value permitted for similar conductors that are not taps. A. Faulted b. Tap c. Magnetic d. Copper-likearrow_forward19.Before determining the algebraic sum of voltages using Kirchhoff's voltage law, you must first determine which end of ____________ element is positive and which is negative.arrow_forwardGive the raceway size required for each of the following conductor combinations: 1. Three, 1/0 AWG and one, 1 AWG, Type THW in EMTarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Optical fiber cables, how do they work? | ICT #3; Author: Lesics;https://www.youtube.com/watch?v=jZOg39v73c4;License: Standard Youtube License