Mindtap Electrical, 4 Terms (24 Months) Printed Access Card For Herman's Delmar's Standard Textbook Of Electricity, 6th (mindtap Course List)
6th Edition
ISBN: 9781305634312
Author: Herman, Stephen L.
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 30, Problem 2RQ
To determine
The type of voltage that is produced in all rotating armatures.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A wave wound DC generator has 6 poles and the armature has 756
conductors. How fast should the armature rotate if the flux is 20 mWb per
pole and 240 V is desired?
A dc machine has 4-pole, wave wound armature with 46 slots and 16 conductors per slot. If induced voltage in the armature is 480 V at 1,200 rpm, determine the flux per pole
2- A 4-pole, wave-wound d.c. shunt generator has an armature winding consisting
of 300 turns each of 0.0020. The armature resistance is
a) 0.152 b)0.62 c) 0.30 d) none of above
Chapter 30 Solutions
Mindtap Electrical, 4 Terms (24 Months) Printed Access Card For Herman's Delmar's Standard Textbook Of Electricity, 6th (mindtap Course List)
Ch. 30 - What is a generator?Ch. 30 - Prob. 2RQCh. 30 - Prob. 3RQCh. 30 - Prob. 4RQCh. 30 - What are interpoles, and what is their purpose?Ch. 30 - How are interpoles connected in relation to the...Ch. 30 - Prob. 7RQCh. 30 - How is the series field connected in relation to...Ch. 30 - How is the shunt field connected in relation to...Ch. 30 - What is armature reaction?
Ch. 30 - What is armature reaction proportional to?Ch. 30 - What are eddy currents?Ch. 30 - What condition characterizes overcompounding?Ch. 30 - What is the function of the shunt field rheostat?Ch. 30 - Explain the difference between cumulative- and...Ch. 30 - Explain the difference between cumulative- and...Ch. 30 - What three factors determine the amount of output...Ch. 30 - What is the voltage regulation of a DC generator...Ch. 30 - Prob. 19RQCh. 30 - Prob. 20RQCh. 30 - You are working as an electrician in a large steel...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- In DC machine winding, number of commutator segments is equal to number of armature coil sides ) number of armature coils ) number of armature conductors ) number of armature turnsarrow_forwardA four-pole lap-wound DC machine armature has 54 slots with single-turn coils. How many armature conductors are required if there are two coil sides per slot?arrow_forwardThe voltage induced in 8 poles lamp wound generator is 120 V with armature resistance = 0.3 2. What will be the terminal voltage at a load = 3.6 A when the machine is rewound as a wave?arrow_forward
- Explain the following armature winding terminologies (i)commutator Pitch (ii)Coil Side (iii)Pole Pitcharrow_forwardThe strength of the rotating magnetic field in a three phase induction motor is equal to times the flux produce ...... ....... in one of the phase windings. 1.25 1 O 1.5arrow_forwardName the principal parts of a rotating electrical machinearrow_forward
- A4-Pole, duplex wave-wound de generator, has 144 slots with 2 coils per slot, each having two turns. If the flux per pole is is 20mWb and the armature rotates at 1500 rpm and the armature develops a power of 25kW, what will be the current in each path (in Amp)?arrow_forwardQ2) A wave wound DC generator armature has six - pole and 50 slots. Each slot contains 20 conductors. The required generated voltage is 250 V. a) What would be the speed of the armature, if flux per pole is 0.007 Wb? b) If the armature is rewound as lap formation and run at the same speed you found in part a) above, what will be the generated voltage? The flux per pole is 0.007 Wb.arrow_forwardA 8 pole wave wound dc shunt generator runs at a speed of 1450 rpm, has an armature and shunt field resistance of 0.7 Q and 240 Q respectively. The armature has 910 conductors and flux per pole is 0.115 Weber. If the lamp load connected has a resistance of 20 0, determine (i) Generated EMF (ii) Total Resistance (iii) Armature Current (iv) Terminal Voltage.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Delmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage Learning
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning