Question
Chapter 30, Problem 15R
To determine
Mention how the circuit feeding the receptacle outlet located within 5 ft of the tub is protected.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
QUESTION 5
A duplex receptacle is installed on a 4-inch square raised metal cover and mounted on a 4-inch square metal box.If the grounding terminal of the receptacle is connected to the grounded metal box, which of the following requirements would also apply to the installation of the duplex receptacle?
a
It must be secured by at least two screws.
b
The single 6/32 screw holding it in the cover must be tight.
c
It must be secured directly to the 4 inch square box.
d
It is not permitted to be installed in raised covers.
QUESTION 8
Enclosures that are not over 100 cubic inches in size and which have two conduits supported within three feet on either side of the enclosure and the enclosure does not contain devices or support fixtures shall not be required to have the enclosure supported if the conduits are _____.
a
installed with locknuts inside and outside enclosure
b
shoulders of fittings outside and locknuts inside the box
c
rigid nonmetallic conduits
d
threaded into hubs identified for the purpose
Question 17
The electrode and circuit must provide a
flow path to the earth with less than
of resistance.
5
10
25
30
Question 18
A(n) is a permanent conductor
placed across a water meter to provide a
continuous flow path for ground
current.
shunt
bare conductor
electrode
bonding conductor
Chapter 30 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Question 8.aWhich article of the NEC describes the proper placement of outlets inthis type of room? Also, based on the given load what type of outlets areneeded for this room? Question 8.bPart 1: According to the NEC. What's the minimum highallowed for each outlet?Part 2: What are the best locations to install the outlets?Part 3: How many feet an outlet should be located at the wallfrom the floor, used to power a light fixture?arrow_forwardIn a bathroom, at least one receptacle must be installed within ____ inches of the outside of the basin.arrow_forwardA device used in kitchen serving hotels dining rooms club houses and restaurants is__________. a.) Grease basin b.) Yard basin c.) Garage basin d.) Oil catch basinarrow_forward
- Assuming that an outlet box for the entry ceiling has a fixture stud but has external cable clamps, what size box could be installed? Show calculations for both metal and nonmetallic boxes. ___________arrow_forwardoleg is using a multimeter to test the circuit branch he's just installed. after turning off the current to the circuit at the service panel, he'll first attach one probe to the ----- in the end of the run. a. black wire b. box c. white wire d. ground wire Please answer with explanation In typing formatarrow_forwardTOPIC: Power Systems, Power Plants & IlluminationINSTRUCTIONS:- Answer in this format: Given, Illustration, Required Conversion, Solution, Final Answer.- Step-by-step solution, do not skip even simple calculations to avoid confusion.- If answered in written form, make sure it is readable.PROBLEM:In hazardous locations, the use of non-metallic conduit shall be permitted provided it is buried NOT less than ___________ blow the earth level. 400 mm 600 mm 1000 mm 500 mmarrow_forward
- The recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________arrow_forwarda. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forwardf.1. Since the footing or foundation is generally part of the grounding electrode system, the _______electrode is one of the first electrodes installed.A. metal water pipeB. plateC. concrete-encasedD. ground ringf.2. When you're connecting the grounding electrode conductor to a metal water pipe as it enters a building,the connection must be made within _______ feet of the pipe's entrance to the building.A. 10B. 5C. 15D. 7f.3. Which National Electrical Code table is used for sizing grounding electrode conductors?A. Table 250.102(C)(1)B. Table 250.66C. Table 250.122D. Table 250.118(6)(a)arrow_forward
- 13. If an equipment bonding jumper is run external to a raceway, it must be less than _______ feet.A. 6B. 2C. 4D. 5arrow_forwardRefer to the specifications in the back of this text following Chapter 33. a. What electrical codes must be conformed to? ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ b. What is the wiring method to be used in the workshop? ________________________________________________________________________ c. What size conductors are to be used for the lighting branch circuits? ______________________ AWG the small-appliance branch circuits? ______________________ AWG d. What section of the specifications tells us the size of the service entrance to be installed for this residence?arrow_forwardThe plans indicate that you should install a 300 amp branch circuit in schedule 40 PVC with a 4AWG equipment grounding conductor. However, you did not have any 4AWG so you pulled 10AWG instead. With a load connected, the normal circuit current will be ___arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT