Concept explainers
Define the Service Point. –
______________
Define the term Service Point.
Explanation of Solution
Discussion:
The point of connection between the facilities of serving utility’s supply and customer’s premises wiring is called the ‘service point’.
Refer to an article NEC 100, the service point is in the meter base for a typical underground service. The service point is at the connection where the premises wiring is connected to utility service drop conductors for an overhead device. The electrical utility is responsible for the conductors and equipment on supply side of service point where the customer’s premises wiring is responsible for the equipment and conductors on load side of service point.
Conclusion:
Thus, the term service point is defined.
Want to see more full solutions like this?
Chapter 27 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Additional Engineering Textbook Solutions
ANALYSIS+DESIGN OF LINEAR CIRCUITS(LL)
Programmable Logic Controllers
Electric Motors and Control Systems
Electrical Engineering: Principles & Applications (7th Edition)
Principles and Applications of Electrical Engineering
Electronics Fundamentals: Circuits, Devices & Applications
- How many circuit wires enter the entry ceiling box? How many equipment grounding conductors enter the entry ceiling box?arrow_forwardHi, I need a correct answer for this assignment question Thanksarrow_forwardThe air interface connecting phones, antennas, and towers in mobile networks is completely devoid of wires and cables. Is there anything else required for the backhaul of cellular signals?arrow_forward
- draw a schematic diagram of the jumpers connected to the front panel of a computer system unit.arrow_forwardDO NOT COPY FROM OTHER WEBSITES Upvote guarenteed for a correct and detailed answer. Thank you soo much!arrow_forwardWhat does the attached system diagram represent? Specify number of wires used.arrow_forward
- NOTES: -Pls Do It By Using Computer Line, -(Minimum 350 words.) Reference must be mentioned at the end of the report.arrow_forwardWhich section of the Code prohibits telephone cables from being installed in the same box or enclosure or from being pulled into the same raceway as light and power circuits? _____arrow_forwardWhen used as service equipment, a panelboard (load center) must be ______________________ that is suitable for use as service equipment, 230.66. If the panelboard (load center) contains the main service disconnect, it must be clearly marked ____________________________________, 230.70(B).arrow_forward
- 16. The _______ point is where the facilities of the serving utility and the premises wiring connect.A. groundedB. neutralC. serviceD. bondingarrow_forwarda. The service head must be located (above) (below) the point where the service-drop conductors are spliced to the service-entrance conductors. (Circle the correct answer.) b. What Code section provides the answer to part (a)? ___________________arrow_forwardA transfer switch shall be required for all fixed or portable optional standby systems for buildings or structure at which an electric utility is either the normal or standby source, unless permitted by an exception True or False?arrow_forward
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT