Interpretation:
The effect of flow rate of carrier gas on
Concept introduction:
Gas chromatography is efficiently used for the compounds that have high vapor pressures which allow them to pass through a GC column.
A gas chromatography does not identify compounds if unknown samples are loaded into the column. GC is one of type of partition chromatography, where the sample that has to be analyzed get adsorbed on the stationary phase.
The stationary phase is formed by high boiling nonvolatile liquid, usually a
The components of gas-liquid chromatography are as follows:
- High-pressure pure carrier gas source
- Flow controller
- Heated injection port
- Column and column oven
- Detector
- Recording device or data station
(b)
Interpretation:
The effect of temperature of the column on
Concept introduction:
Gas chromatography is efficiently used for the compounds that have high vapor pressures which allow them to pass through a GC column.
A gas chromatography does not identify compounds if unknown samples are loaded into the column. GC is one of type of partition chromatography, where the sample that has to be analyzed get adsorbed on the stationary phase.
The stationary phase is formed by high boiling nonvolatile liquid, usually a polymer. An inert gas like helium or nitrogen is utilized to form mobile phase. In GC, no interaction of compound with mobile phase occurs, unlike LC and TLC. The inert gas that makes the mobile phase carries the compound down the column when it is in vapor state. The compounds present in the mixture divide themselves between the gas phase and the liquid phase in the column in an equilibrium.
The components of gas-liquid chromatography are as follows:
- High-pressure pure carrier gas source
- Flow controller
- Heated injection port
- Column and column oven
- Detector
- Recording device or data station
Want to see the full answer?
Check out a sample textbook solutionChapter 20 Solutions
Laboratory Techniques in Organic Chemistry
- Can paper chromatography be used to separate and identify very volatile substances? Why? Please explain comprehensively.arrow_forwardA student researcher performed a chromatographic separation of caffeine and aspartame. The retention time for caffeine, te, was found to be 200.8 s with a baseline peak width, we, of 16.1 s. The retention time for aspartame, ta, was 258.7 s with a baseline peak width, wa, of 20.6 s. The retention time for the unretained solvent methanol was 44.2 s. Calculate the average plate height, H, in micrometers for this separation, given that it was performed on a 22.1 cm long column. H = Calculate the resolution, R, for this separation using the widths of the peaks. R = 88.2 R₂5N = 3.16 Calculate the resolution if the number of theoretical plates were to increase by a factor of 2.5. 3.533 Incorrect μmarrow_forwardIn reversed phase HPLC, how will the retention time of a component of a mixture vary with the polarity of its molecules? Explain your answerarrow_forward
- One method for the quantitative determination of the concentration of constituents in a sample analyzed by gas chromatography is area normalization. Here, complete elution of all the sample constituents is necessary. The area of each peak is then measured and corrected for differences in detector response to the different eluates. This correction involves dividing the area by an empirically determined correction factor. The concentration of the analyte is found from the ratio of its corrected area to the total corrected area of all peaks. For a chromatogram containing three peaks, the relative areas were found to be 16.4, 45.2 and 30.2, in order of increasing retention time. Calculate the percentage of each compound if the relative detector responses were 0.60, 0.78 and 0.88, respectively.arrow_forwardA student researcher performed a chromatographic separation of caffeine and aspartame. The retention time for caffeine, tc, was found to be 209.6 s with a baseline peak width, w., of 14.4 s. The retention time for aspartame, ta, was 260.0 s with a baseline peak width, wa, of 21.2 s. The retention time for the unretained solvent methanol was 49.2 s. Calculate the average plate height, H, in micrometers for this separation, given that it was performed on a 22.1 cm long column. H = um %3D Calculate the resolution, R, for this separation using the widths of the peaks. R = Calculate the resolution if the number of theoretical plates were to increase by a factor of 2. R2N =arrow_forward1. Methanol and ethanol are separated in a capillary GC column with retention times of 370 and 385 s, respectively, and half widths (W₁/2) of 9.42 and 10.0 s. An unretained butane peak occurs at 10.0 s. Calculate the separation factor and the resolution.arrow_forward
- In lon Chromatography retention times and the resolution between adjacent peaks can be affected by changing the concentration of the mobile phase. In the ICS2000 instrument used here, the mobile phase is potassium hydroxide. Which ONE of the following responses best explains the effect of increasing the mobile phase concentration on the peak retention times and the resolution between adjacent peaks? As the mobile phase hydroxide concentration is increased the peak retention times decrease and the resolution between adjacent peaks decreases As the mobile phase hydroxide concentration is increased the peak retention times increase and the resolution between adjacent peaks decreases As the mobile phase hydroxide concentration is increased the peak retention times increase and the resolution between adjacent peaks decreases As the mobile phase hydroxide concentration is increased the peak retention times increase and the resolution between adjacent peaks increasesarrow_forwardIn color chromatography of plant pigments, what complications would a dried-out column (solvent level is below the top of the silica) introduce to the elution and isolation of pigments?arrow_forward(a) An analyst has conducted a separation of a mixture of substance X and Y using liquid chromatography technique. The column used is 30-cm long and the flow rate was 0.65 mL/min. The chromatogram obtained is shown in Figure Q1.1. i) Determine the adjusted retention times for substance x and y. ii) Calculate the retention factors for substance x and y. iii) Calculate the resolution of the two peaks. Then, describe the quality of separation between the two adjacent peaks. iv) Calculate the plate height value of the column.arrow_forward
- Calculate the separation factor (or selectivity factor), between two compounds, 1 and 2, whose retention volumes are 6mL and 7mL, respectively. The dead volume of the column used is 1mL. Show that this factor is equal to the ratio of the distribution coefficients K2/K1 of these compounds tR(1)<tR(2).arrow_forwardA chromatogram of a mixture of species A, B, and C provided the following data: a) Define "Retention time". b) Calculate the resolution between species A and B. c) Calculate the retention time of species B necessary to separate it from species A with a resolution of 1.5.arrow_forwardBriefly explain how cation exchange chromatography can used in protein separation?arrow_forward
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning