Concept explainers
The possible cause of the indication of tester (120 volts) between ungrounded (short) slot and grounded (long) slot, and also the same indication between grounded (long) slot and grounding slot (U-shaped).
Answer to Problem 1RQ
Reversed polarity at the receptacle
Explanation of Solution
In residential wiring, the duplex receptacle is the most common receptacle type. On one strap, there are two receptacles. Each receptacle can control an electrical load that is connected by a cord and plug.
A voltage tester is a device that displays estimated voltage values or simply demonstrates whether or not a voltage exists.
A voltage tester is used to evaluate a 15-ampere, 125-volt rated duplex receptacle. Between the short ungrounded and long grounded slots, the tester shows 120 volts. Between the long grounded slot and the U-shaped grounding slot, the tester shows 120 volts.
The likely cause of the indication of tester (120 volts) between ungrounded (short) slot and grounded (long) slot and also the same indication between grounded (long) slot and grounding slot (U-shaped) is Reversed polarity at the receptacle.
Conclusion:
The likely cause of the indication of tester (120 volts) between ungrounded (short) slot and grounded (long) slot and also the same indication between grounded (long) slot and grounding slot (U-shaped) is reversed polarity at the receptacle.
Want to see more full solutions like this?
Chapter 20 Solutions
MindTap Electrical for Fletcher's Residential Construction Academy: House Wiring, 5th Edition [Instant Access], 4 terms (24 months)
- Small-appliance branch circuits and laundry branch circuits installed in a dwelling must have a rating of at least__________ amperes. This information is found in NEC Section __________. (Objective 6-2)arrow_forwardCalculate the minimum copper conductor size needed for a 120/240-volt electric range branch circuit. The electric range has a nameplate rating of 12 kW. Show all work. (Objective 6-2)arrow_forwardWhen wiring a split-wired receptacle, it is recommended that the part of the duplex receptacle controlled by a switch be the _______half and the part that is hot at all times is the ______ half. (Objective 18-3)arrow_forward
- Describe when an electrician would use a new work box and an old work box. (Objective 2-3)arrow_forwardA ground resistance meter is used to determine the amount of resistance__________.(Objective 4-7) a. through a grounding electrode to the earth b. though a grounding electrode to the metal frame of an electrical cabinet c. from one end of a grounding conductor to the other end d. from a grounded conductor to the eartharrow_forwardDirections: Circle T to indicate true statements or F to indicate false statements. The higher the resistance in an electrical circuit, the lower the amount of current that can flow in the circuit. (Objective 1-2)arrow_forward
- The minimum amount of free conductor required at an electrical box used in residential wiring for termination purposes is______________ inches. As long as the box has no dimension Larger than 8 Inches (200 mm), there must be at Least ______ inches of free conductor extending out from the box opening. Name the NEC section that covers this wiring practice. (Objective 9-3)arrow_forwardwo.t 2-22 mm (n.) 2-22mm (d,) 3-22mm (f) 12m- 23cm 8cm w 8.1 38 cm. P.L 40cm بسته 09- cm 2.6 m 23-22mm (2) -1.22mm (h) 1-22mm) -1-37m 10mm STPS. @12mm c/c -21mx18m 2.1m L38 cm 25 mm CLEAR. COVER 3-22 mm (c) -6-22 mm (d) -30 cm -6-22mm (c) 38 cm SECTION-1-1 10 mm 105 -2-22m. -2-22 mm STRAIGHT 2 IX -3-22 mm (f) PLAN OF 38 cm x 25cm. COLN. 25-22mm (4.h. i) -10 mm STPS @25cm -5.5m BINDER 23 cm 3-22 mm (c) 1-22 mm. (8) 10mm STIRRUPS- -22 mm @9 cm c/c (0) -22 mm @ 9cm c/c (b) -20 NOS. RODS (LONG SIDE) 17 NOS RODS (SHORT SIDE) 2 -1.37m- -/4-18mm STR 12 cmc/c -5-22 mm (disf) -4-22mm (h. i) 125 cm SECTION 2-2 -50mm CLEAR COVER -8 cm LEAN CONC. (1:4:8)novations 38 -Prepare a complete schedule of bars of the portal frame as shown in the 4-15. Assume weight of 22mbar-2-98 kg/rm and 10mm bar-0.62 kg/rm. Twar 469arrow_forward
- Residential Construction Academy: House Wiring (M...Civil EngineeringISBN:9781337402415Author:Gregory W FletcherPublisher:Cengage Learning