True or False? A faulty voltage regulator can only cause a no-charge condition.
The statement “A faulty voltage regulator can only cause a no-charge condition” is true or false.
Answer to Problem 1RQ
The given statement “A faulty voltage regulator can only cause a no-charge condition” is false.
Explanation of Solution
Voltage regulators are used to control and maintain the voltage at a constant level. It regulates the charging voltage of alternator.
In case of faulty voltage regulator, battery electrolyte is depleted quickly. This happens when battery is constantly over-charged. This condition is also known as over-charging condition.
Another symptom of faulty voltage regulator is dead battery. Due to this, battery loses the ability to charge or stop altogether. This condition is a no-charging condition.
Hence, a faulty voltage regulator can cause both no-charge condition and over-charging condition.
Conclusion:
Thus, the given statement “A faulty voltage regulator can only cause a no-charge condition” is false.
Want to see more full solutions like this?
Chapter 19 Solutions
Automotive Technology: A Systems Approach (MindTap Course List)
- True or False? A zero reading on an ohmmeter means the circuit or component is open.arrow_forwardTrue or False: Pressures below atmospheric pressure cannot be detected.arrow_forwardTrue or False: When troubleshooting a small system, the first step is to attach the high- and low-pressure gauges.arrow_forward
- True or False? A lab scope is a visual voltmeter that shows voltage over a period of time.arrow_forwardTrue or False? Coil secondary resistance is typically very low, less than 1 ohm.arrow_forwardWhich of the following uses a permanent magnet and two electromagnets? Air-core gauge Balancing coil gauge Quartz analog gauge D' Arsonval gaugearrow_forward
- Which of the following is false? The air bag igniter assembly is a spark plug-type device with two pins that current must jump across. The air bag igniter assembly creates a spark that ignites a canister of gas generating zerconic potassium perchlorate. The air bag igniter assembly is housed in the module assembly. None of the above.arrow_forwardThe A/C compressor cycles rapidly, and air coming from the vents is only slightly cool. Technician A says the problem could be a low refrigerant charge. Technician B says the problem could be a defective thermostatic switch. Who is right? Group of answer choices Technician A Technician B Both A and B Neither A nor B PreviousNextarrow_forwardWhich of the following tests would not be performed to check for high resistance in the battery' cables? Cranking voltage test Insulated circuit resistance test Starter relay by-pass test Ground circuit resistance testarrow_forward
- Automotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage LearningAutomotive TechnologyMechanical EngineeringISBN:9781337794213Author:ERJAVEC, Jack.Publisher:Cengage,Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
- Welding: Principles and Applications (MindTap Cou...Mechanical EngineeringISBN:9781305494695Author:Larry JeffusPublisher:Cengage LearningElectrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage Learning