Question
Chapter 18, Problem 10RQ
To determine
The section of the NEC®requiredfor re-identification of conductor when connecting a switch loop.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
5
Chapter 18 Solutions
Residential Construction Academy: House Wiring (MindTap Course List)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Similar questions
- Small-appliance branch circuits and laundry branch circuits installed in a dwelling must have a rating of at least__________ amperes. This information is found in NEC Section __________. (Objective 6-2)arrow_forwardThe most often used category-rated UTP cable for voice and data wiring from various outlets back to the service center or other distribution device in a residential application is______. (Objective 16-3)arrow_forwardCalculate the minimum copper conductor size needed for a 120/240-volt electric range branch circuit. The electric range has a nameplate rating of 12 kW. Show all work. (Objective 6-2)arrow_forward
- The metal frame of a switch or receptacle is called a (n) ______ or ______. (Objective 18-3)arrow_forwardIf Type SER service entrance cable is used by an electrician to feed a subpanel from a main panel, the cable must be secured within _________of the panel enclosures and at Intervals not exceeding___________. Name the NEC section that states this requirement. (Objective 8-7)arrow_forwardThe minimum amount of free conductor required at an electrical box used in residential wiring for termination purposes is______________ inches. As long as the box has no dimension Larger than 8 Inches (200 mm), there must be at Least ______ inches of free conductor extending out from the box opening. Name the NEC section that covers this wiring practice. (Objective 9-3)arrow_forward
- Although it is not a specific requirement, most electricians feel that the best place to start a cable run for a branch circuit is at the service panel or subpanel. Explain why this is so. (Objective 11-3)arrow_forwardWhen wiring a split-wired receptacle, it is recommended that the part of the duplex receptacle controlled by a switch be the _______half and the part that is hot at all times is the ______ half. (Objective 18-3)arrow_forwardDirections: Circle T to indicate true statements or F to indicate false statements. The higher the resistance in an electrical circuit, the lower the amount of current that can flow in the circuit. (Objective 1-2)arrow_forward
- A wall-mounted luminaire (fixture) weighing not more than_________ pounds is permitted to be supported on a device box provided the luminaire or its supporting yoke is secured to the box with no fewer than two 6-32 or Larger screws. Name the NEC section that covers this requirement. (Objective 9-5)arrow_forwardDescribe how a white Insulated conductor in a cable assembly is reidentified as an ungrounded hot conductor. Name the NEC section that covers this wiring situation. (Objective 9-4)arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Residential Construction Academy: House Wiring (M...Civil EngineeringISBN:9781337402415Author:Gregory W FletcherPublisher:Cengage Learning
Residential Construction Academy: House Wiring (M...
Civil Engineering
ISBN:9781337402415
Author:Gregory W Fletcher
Publisher:Cengage Learning