What is the difference between dry air and atmospheric air?
The difference between dry air and atmospheric air.
Explanation of Solution
The presence of humidity is the biggest difference between dry air and atmospheric air. Humidity is present in atmospheric air whereas there is no humidity in dry air.
Dry air is stated as air that contains zero water vapor and has a low relative humidity. Atmospheric air is called as the air which is usual under atmospheric conditions and is unlike for changed locations and dependent on wind patterns. They usually contain humidity.
Hence, dry air is air with no humidity and atmospheric air has humidity.
Want to see more full solutions like this?
Chapter 14 Solutions
EBK THERMODYNAMICS: AN ENGINEERING APPR
Additional Engineering Textbook Solutions
Shigley's Mechanical Engineering Design (McGraw-Hill Series in Mechanical Engineering)
Mechanics of Materials (10th Edition)
Applied Statics and Strength of Materials (6th Edition)
Engineering Mechanics: Statics & Dynamics (14th Edition)
Vector Mechanics for Engineers: Statics and Dynamics
- For air at 80 8C dry bulb temperature and 20 8C dew-point temperature, determine its humidity, relative humidity, wet bulb temperature, enthalpy, humidvolume and humid heat.arrow_forwardthe maximum amount of water vapor in air at 20c is 15.0 g/kg. If the relative humidity is 60%, what is the specific humidity of this air?arrow_forward3. Why dry air and water vapor during calculating the properties of moist air are treated separately, explain.arrow_forward
- Q 6: The air in a room has a pressure of 101.3 kPa and a dry bulb temperature of 24°C, with a wet bulb temperature of 17°C. Using the psychrometric chart determine the humidity ratio, the enthalpy, the relative humidity, the dew point temperature, and the specific volume of the humid air. (Ans : 0.0094 kgv/kgda, 47.6 kJ/kgda, 50%, 12.9°C, 0.854 m/kgda) 3arrow_forwardWhat is air-mass weather?arrow_forwardWhat is the state of a water vapor at dew point temperature and dry-bulb temperature?(use the psychometric chart to determine the state of the steam)arrow_forward
- Air enters a cooling tower at a rate of 1100 cubic meters per minute, at 15°C and 65% relative humidity. Atmospheric pressure is 100 kPa. Water enters the tower at 38°C and leaves at 17°C. Air leaves the tower at 31°C and saturated. Using a psychrometric chart calculate the absolute humidity of the air leaving the cooling tower. 0.029 kg water vapour/kg air 0.069 kg water vapour/kg air O 0.0101 kg water vapour/kg air 0.364 kg water vapour/kg airarrow_forward"For an air-water system at a given moisture content, the temperature decreases as the humidity increases."Is this statement true or false? Shouldn't it be relative humidity?arrow_forward1. In the process of air conditioning in a humidifier, the air at a dry bulb temperature of 20 °C and 25% RH increases its RH to 40%. Determine the amount of moisture added in the humidifier per kg of dry air. = (kg water/kg air). 2. The air has a dry bulb temperature of 34 °C and a wet bulb temperature of 22°C. The liquid is heated in a heater so that the dry bulb temperature increases to 80 °C. Then the air is passed through the corn kernels to dry. The air coming out of the corn kernels is at bulb temperature. dry 55 °C Then this air is passed to the dehumidifier to reduce its RH to 10%. Draw the course of the air change process on a psychrometric diagram. The rate of air flow through the corn kernels and dehumidifier is 4.0 m/s and the cross-sectional diameter of the pile is 0.7 m. a) Determine the amount of water content lost from the pile of corn kernels (in grams of water/second) b) Determine the amount of water content lost from the air when passing through the…arrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY