Textbook Question
Book Icon
Chapter 12, Problem 8R

Duplex receptacles connected to the 20-ampere small-appliance branch circuits in kitchens and dining rooms (Circle the correct answer):

  1. a. may be rated 15 amperes.    (True)    (False)
  2. b. must be rated 15 amperes.    (True)    (False)
  3. c. may be rated 20 amperes.    (True)    (False)
  4. d. must be rated 20 amperes.    (True)    (False)
Blurred answer
Students have asked these similar questions
7.B. The size of a grounding electrode conductor for a service or separately derived system is generally basedon the size of the largestA. ungrounded supply conductor.B. equipment grounding conductor.C. grounded electrode.D. bonding jumper.7.C. Which of the following statements about bonding is true?A. The joint or termination must offer opposition in the circuit for effective electrical connections.B. Effective bonding keeps impedance high if a fault should occur.C. The entire electrical safety circuit is only as good as its strongest bonded link.D. Bonding connections must endure high levels of fault current until overcurrent protective devices can operate.
Refer to the National Electrical Code or the working drawings when necessary. Whereapplicable, responses should be written in complete sentences.A 300-kilovolt-ampere transformer bank consisting of three 100-kilovolt-amperetransformers has a 3-phase, 480-volt delta primary and a 120/240-volt, 3-phase, 4-wiredelta-connected secondary.For problems 1 through 4 show calculations and/or source of information 1. What is the full-load current in the primary? 2. What is the full-load current in the secondary?
Refer to the National Electrical Code or the working drawings when necessary. Whereapplicable, responses should be written in complete sentences.A 300-kilovolt-ampere transformer bank consisting of three 100-kilovolt-amperetransformers has a 3-phase, 480-volt delta primary and a 120/240-volt, 3-phase, 4-wiredelta-connected secondary.For problems 1 through 4 show calculations and/or source of information. 1. What is the proper rating of the fuses to install for overcurrent protection of thesecondary?2. What is the kilovolt-ampere of the bank if one of the transformers is removed?
Knowledge Booster
Background pattern image
Electrical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
How Thermistors Work - The Learning Circuit; Author: element14 presents;https://www.youtube.com/watch?v=g683mTSZ2i0;License: Standard Youtube License