Electrical Transformers and Rotating Machines
4th Edition
ISBN: 9781305494817
Author: Stephen L. Herman
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 10, Problem 7RQ
What size conductor should be used to connect the primary of the transformer described in question #6? Assume the conductor to be copper with type THW insulation.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
what is the smallest
gage size copper wire
that will limit the
conductor voltage
drop to 5v when 120
vac is supplied to a 6-A
load
Question 2 Calculate the amount of DC current required for the magnetic circuit given below to generate a
flux density of 1.0 T in the airgap. The details are
Number of turns, N = 400
The core is made up of steel, the B-H characteristic has been given below
The magnetic core length, le = 500 mm
The airgap length, Ig = 2 mm
The cross-sectional area of the core, Ag = 100 mm²
Neglect leakage and fringing.
Core
Cross-sectional
i(1)
area
as
Air gap
Magnetic path
length
Figure 1
2.0
1.8
B-H Curves for Various Metals
Steel
1.6
1.4
Magnetic
Saturation
1.2
1.0
0.8
Iron
근 0.4
Air
0.2
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
Magnetic Field Strength - H (A/m)
Figure 2
Flux Density - B (T)
Find the value of the currents I1 and 12.
100 ohm
5V
5V
100 ohm
12
O a. 1=-0.3A, 12=-0.1A
O b. 11=0.3A, 12=0.1A
Oc. 11=0.05A, 12=0.1A
O d. 11=0.1A, 12=0.2A
Chapter 10 Solutions
Electrical Transformers and Rotating Machines
Ch. 10 - Prob. 1RQCh. 10 - What size overcurrent device should be used to...Ch. 10 - Prob. 3RQCh. 10 - The secondary of the transformer in question #3...Ch. 10 - A 10 kVA transformer has a primary voltage of 208...Ch. 10 - A 10 kVA transformer has a primary voltage rating...Ch. 10 - What size conductor should be used to connect the...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A load impedance of 52 Ω is connected to the secondary winding of the transformer in question 3. How much current will flow in the secondary?arrow_forwardIf the secondary of the transformer in question 5 supplies a current of 9.6 amperes to a load, what is the primary current? (Disregard excitation current.)arrow_forwardIf a single-phase load is connected across the two line conductors and neutral of the transformer in question #2, and one line has a current of 80 amps and the other line has a current of 68 amps, how much current is flowing in the neutral conductor?arrow_forward
- Assume that a primary current of 75 amperes flows through the windings of the transformer in question 4. How much current will flow in the secondary winding?arrow_forwardA 2 AWG Copper conductor is 450' long what is the resistance of the wire? assumed the ambient temp to be 20゚Carrow_forwardA 480-volt three-phase load is rated at 34.5 kVA. It is to be supplied with variable three-phase voltage. Because the load is continuous, the transformers ratings are to be increased by 1.25% of the rated load. Three variable autotransformers are used to supply this load. Refer to Table 4-2 and determine the standard size of each transformer that should be used to make this connection.arrow_forward
- A current transformer has a ratio of 600:5. If three loops of wire are wound through the transformer core, how much primary current is required to produce 5 amperes of current in the secondary winding?arrow_forwardA 10 kVA transformer has a primary voltage of 208 volts and a secondary voltage of 120 volts. What size circuit breaker should be used to protect the primary winding?arrow_forwardIf dual-element time delay fuses are to be used as the short circuit protective device, what size fuses should be used to protect the circuit in question #12? Five 5 HP, three-phase motors with NEMA code B are connected to a 240-volt line. The conductors are copper with type THWN insulation. What size conductor should be used to supply all of these motors?arrow_forward
- al Three coils each having resistance of 29 N are connected in star across 422 V, 50 Hz supply. Then the total power consumed is O 211.77 W O 3545.51 W O 730.95 W O 6140.83 Warrow_forwardA 10 kVA transformer has a primary voltage rating of 240 volts and a secondary voltage rating of 480 volts. The transformer is connected to a circuit protected by a 100 ampere circuit breaker. The secondary is protected by a 25-ampere fuse. Does the primary require separate overcurrent protection?arrow_forwardCalculate the resistance between A and B: 1 ohm 5 ohm ww 4 ohm B 2 ohm 6 ohm 3 ohm 7 ohmarrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Electrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningUnderstanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Understanding Conduction and the Heat Equation; Author: The Efficient Engineer;https://www.youtube.com/watch?v=6jQsLAqrZGQ;License: Standard youtube license