Question
error_outline
This textbook solution is under construction.
Students have asked these similar questions
a) Interrelate the core saturation and different characteristics of over-current relay.
b) Mention the reason, how the very inverse characteristics of over current relay is obtained if the core is made to saturate at a later stage.
what is the difference between plug setting and pick up value of overcurrent relays?
Q3. In a % differential scheme, figure shown below, the two CTs have nominal ration of 100:1. The CT
errors for a through fault current of 5000 A are as following:
CT1
CT2
Ratio error:
10%
10%
Phase angle error:
5%
-5%
Compute following:
i)
The spill current of the OC relay in the spill path.
ii)
If the relay is 50% biased, examine whether relay will trip or remain stable
CT,
CT
Ir
CB
C.B.
メx
Egu inder
Ne
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Find the driving point impedance.( need only handwritten solution .otherwise downvote.)arrow_forwardFind the line fault current of the feeders shown in the figure and the T.S.M of Relay 2. Knowing that actual time of operation of Relay 2 is 1.4 Sec, the time margin between the two relays is 0.6 Sec, and the time setting multiplier (T.S.M.) of Relay 1 is 0.4. Use the I.D.M.T curve shown below. Bec 500/5 00/S CB2 Relay 2 160% Relay 1 120% PSMarrow_forwardBack-up protection is not a good substitute for better maintenance. Discuss. Why are differential relays more sensitive than overcurrent relays ? What is the difference between a balanced voltage relay and a Translay relay ?arrow_forward
- In back up protection scheme of power system a 10-Amp, 4-second overcurrent relay having a current setting of 125% and a time setting multiplier of 0.5 connected to supply circuit through a 600/5current transformer when the circuit carries a fault current of 5 kA. The relay manufacturer has provided the values of operating times for the range of PSM from 6 to 7 as 2.4 seconds. Determine the following parameters for this overcurrent relay (i) Pick-up current value (in Amp); (ii) Fault current in relay coil (in Amp); (iii) Plug setting multiplier; (iv) Actual operating time of over current relay(in second)arrow_forwardWhat is the typical response time for MOVS?arrow_forwardExplain the importance of power phase design and VRMs (Voltage Regulator Modules) in motherboard selection for overclocking.arrow_forward
- Which of the following error is caused by a reversal of measured property? a) Dead regionb) Noisec) Non-linearityd) Hysteresise) Tolerancearrow_forward5) Name two power factor correction method. 6) Define Facts and name 2 series connected facts devices 7) Draw a circuit diagram of a Static Synchronous Series Compensator (SSSC) and gives his applications.arrow_forwardDiscuss the importance of relays in power system protection and fault detection.arrow_forward
- Q#2: Demonstrate the open and short circuit test on synchronous machine with the help of circuit diagram. Also discuss that why we need of this test? Solution#2 (to be typed here by the student)arrow_forwardthe relays which are connected in the circuit to be protected through CTs and .V.Ts secondary relays O primary relays auxiliary relays reverse relays PST is an essential component that is used to enhance the efficiency of the AC network True False the time which elapses between the instant when the actuating quantity exceeds the pick-up value to the instant when the relay .contacts close relay time reset time operating time delay timearrow_forwardC.Comments on this statement: "PMUs can be used as a protective relays”. D. What is the ZIB and it role in OPP E Is there any effect of existence of HVDC transmission lines in OPP and state estimations? F. Discuss the challenges that might face application of PMUS/WAMs in any given power system.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
FMPR-103 pt1 l Power Systems Protection v1; Author: L&D for Protection and Control;https://www.youtube.com/watch?v=ELWncjsh5uE;License: Standard Youtube License