1) When you try separating an unknown mixture by normal-phase liquid chromatography with 50% hexane and 50% methyl t-butyl ether, the peaks are too close together. (not resolved) Should you use a higher or lower concentration of hexane in the next run?
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution
Trending nowThis is a popular solution!
Step by stepSolved in 3 steps

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- In an experiment of Reverse Phase chromatography using C-18 stationary phase and a mixture of methanol/ethyl acetate/acetic acid, a researcher tried to separate the 3 compounds shown below. Which compound would have the lowest Rf and which the highest Rf in this experiment? Explain your answer and show any relevant structures.arrow_forwarda. Say you are trying to separate two compounds by column chromatography. You run a column and collect the eluent in five fractions. You analyze each fraction by TLC on the same plate (shown below). Based on the TLC plate, how effective was your separation? Consider the purity of each fraction. - - - - - - - - ----| 1 2 3 4 5arrow_forward"Start the chromatography by adjusting the fraction collector to 130 drops per fraction (about 3 mL)." What is the average volume of a drop?arrow_forward
- The write-up says “A C18-silica column is used in this experiment, a 0.46 x 15 cm column with 5-µm particles. Equilibrate the column with 20 empty column volumes of 0.010 M phosphate buffer (pH 7.2) at a flow rate of 1.2 mL/min before beginning chromatography.” Show the calculation for how much mobile phase you would use (volume) and how long it will take to equilibrate the column.arrow_forwardNext, 2.00 mL of 9.63 mM S was added to 10.00 mL of a solution of unknown concentration of X, and the mixture was diluted to 25.0mL. Chromatographic analysis of this solution produced peak areas of 4822 for X and 4099 for S. What was the concentration of 5 (in mM) of the 25.0mL solution?arrow_forwardOne of the main differences between TLC and column chromatography is the direction in which the mobile phase moves. Group of answer choices True Falsearrow_forward
- thin layer chromatography: What would happen to the Rf value of a compound if you increased the polarity of the mobile phase while using a polar stationary phase? please help me this question! Thank you a lotarrow_forwardQUESTION 3 What is one disadvantage of using column chromatography? It is relatively ineffective at separating most organic compounds The desired compound must be the ≥95% majority compound in the initial mixture for a column to be effective It is only effective at separating room temperature gasses It wastes a significant amount of solventarrow_forwardChromatography 1. External Standard Method A. Calculate the regression equation and the R-squared value. B. Calculate the concentration of cocaine found in the blood samples of the presidentiables. Which presidential candidate “reliably” tested positive for cocaine? 2. Internal Standard Method >Calculate the concentration of party drug X in the blood samples of the presidential candidates. >Suppose the LOD for party drug X is 0.200 ppm, which of the presidential candidates “reliably” tested for party drug X?arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- ChemistryChemistryISBN:9781305957404Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCostePublisher:Cengage LearningChemistryChemistryISBN:9781259911156Author:Raymond Chang Dr., Jason Overby ProfessorPublisher:McGraw-Hill EducationPrinciples of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
- Organic ChemistryChemistryISBN:9780078021558Author:Janice Gorzynski Smith Dr.Publisher:McGraw-Hill EducationChemistry: Principles and ReactionsChemistryISBN:9781305079373Author:William L. Masterton, Cecile N. HurleyPublisher:Cengage LearningElementary Principles of Chemical Processes, Bind...ChemistryISBN:9781118431221Author:Richard M. Felder, Ronald W. Rousseau, Lisa G. BullardPublisher:WILEY

Chemistry
Chemistry
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Cengage Learning

Chemistry
Chemistry
ISBN:9781259911156
Author:Raymond Chang Dr., Jason Overby Professor
Publisher:McGraw-Hill Education

Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning

Organic Chemistry
Chemistry
ISBN:9780078021558
Author:Janice Gorzynski Smith Dr.
Publisher:McGraw-Hill Education

Chemistry: Principles and Reactions
Chemistry
ISBN:9781305079373
Author:William L. Masterton, Cecile N. Hurley
Publisher:Cengage Learning

Elementary Principles of Chemical Processes, Bind...
Chemistry
ISBN:9781118431221
Author:Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:WILEY