Three 2.5 kVA single phase 415 V / 1000 V, 50 Hz transformer are connected in Delta-Star con- figuration to form a three-phase transformer bank. Each transformer has the following equivalent circuit parameters referred to the primary: Req=0.7 N, Xeq = 0.8 , Ro= 4200 , Xo = 5350 N The transformer secondary line current is measured to be 2 A when a star connected load with a lagging power factor of 0.8 is connected. The transformer primary is supplied at its rated voltage. Calculate the total copper losses in the transformer under this operating condition: (a) 48.77 W (b) 59.6 W (c) 67.1 W (d) 26.4 W (e) 70.4 W

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.9P
icon
Related questions
Question
Three 2.5 kVA single phase 415 V / 1000 V, 50 Hz transformer are connected in Delta-Star con-
figuration to form a three-phase transformer bank. Each transformer has the following equivalent
circuit parameters referred to the primary:
Req=0.7 , Xeq = 0.8 , Ro = 4200 , Xo = 5350
The transformer secondary line current is measured to be 2 A when a star connected load with a
lagging power factor of 0.8 is connected. The transformer primary is supplied at its rated voltage.
Calculate the total copper losses in the transformer under this operating condition:
(a) 48.77 W
(b) 59.6 W
(c) 67.1 W
(d) 26.4 W
(e) 70.4 W
Transcribed Image Text:Three 2.5 kVA single phase 415 V / 1000 V, 50 Hz transformer are connected in Delta-Star con- figuration to form a three-phase transformer bank. Each transformer has the following equivalent circuit parameters referred to the primary: Req=0.7 , Xeq = 0.8 , Ro = 4200 , Xo = 5350 The transformer secondary line current is measured to be 2 A when a star connected load with a lagging power factor of 0.8 is connected. The transformer primary is supplied at its rated voltage. Calculate the total copper losses in the transformer under this operating condition: (a) 48.77 W (b) 59.6 W (c) 67.1 W (d) 26.4 W (e) 70.4 W
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning