The NEC requires the grounded conductors to be routed to the service disconnecting means enclosure and bonded to that enclosure. For equipment that is identified as suitable for use as service equipment, this is typically accomplished using a(n)________. a) Bonding conductor b) Grounding conductor c) Equipment grounding conductor d) Main bonding jumper
Q: The insulation rating of class 3, PLTC, FPL, CM cables rated at ____ volts.
A: Ans. 300 volts
Q: If a 1 1/4-in. EMT raceway containing three conductors is already filled to 20%, what is the…
A: Need to find cross sectional area of raceaway
Q: A service disconnection means must be installed adjacent to, within sight of, and no more than…
A: According to question we have to discuss about A service disconnection means must be installed…
Q: 17. In an air compressor system, the distribution piping can be bonded using the A. equipment…
A: Dear student as per our guidelines we are supposed to solve only one question.kindly repost other…
Q: A transfer switch shall be required for all fixed or portable optional standby systems for buildings…
A: According to article 702 - Optional Standby System A fixed or portable optional standby systems…
Q: Question 5 If a building or structure is supplied by a feeder from an outdoor separately derived…
A: Given statement, If a building or structure is supplied by a feeder from an outdoor separately…
Q: 11. What are at least two instances where a splice is allowed to be made in underground consumer's…
A: The power system has to transmit power from the generation side to the load side. For this purpose,…
Q: The frames of ranges, wall-mounted ovens, counter-mounted cooking units, and clothes dryers under…
A: Materials that allow current to flow through them are called conductors. The materials that do not…
Q: 8- Generally as of the operating voltage which of the following options are the correct words that…
A:
Q: 7. What is the object of equipment grounding? Briefl y describe the functions of substation…
A: The object of equipment grounding: To reduce as much as possible the emergence of any voltages in…
Q: If overcurrent protection is not provided at the source of a separately derived system, the…
A: All ordinarily conductive non-current-carrying metal parts and other conductive materials are…
Q: The equipment grounding conductor of a grounding-type receptacle or a branch-circuit extension is…
A: True, The equipment grounding conductor of a grounding-type receptacle or a branch-circuit extension…
Q: when calculating a dwelling lighting load on the "volt-ampere per ft2" basis, the receptacle load…
A: The dwelling lighting load on the "volt-ampere per ft2" basis is to be calculated for the receptacle…
Q: what section of the code prohibits supporting telephone wires from raceways that contain light or…
A: N.E.C. ARTICLE 820 article covers coaxial cable distribution of radio frequency signals or covers…
Q: 12. What is the conduit and wire equivalent to a 400A bus duct with both copper and aluminum?…
A: The National Electrical Code (NEC) is a collection of rules for the secure electrical wiring wiring…
Q: Restrictions on types of conduits used for installing service, sub panel, emergency service panel.
A: We are authorized to answer one question at a time, since you have not mentioned which question you…
Q: what is grading of cables, explain proper in details with block diagram
A: In a single-core cable, the conductor is surrounded by the dielectric material with an outer…
Q: b) Differentiate between Insulated-Neutral and Earthed-Neutral systems as applied to electrical…
A: Question. b) Differentiate between Insulated-Neutral and Earthed-Neutral systems as applied to…
Q: A conductor with continuous white or gray covering shall be used only for the grounded circuit…
A: According to article NEC 200.6, the facts about the identification of the Grounded conductors are…
Q: How far can a 230V, 50A, three-phase load be located from a panelboard if it's fed with 3 AWG…
A: The Length of the load from the panel board is calculated as shown below
Q: Basically, ______receptacles are required to be installed if an equipment grounding conductor is…
A: Article 406 of NEC covers the installation of receptacles of both grounded type and non-grounded…
Q: The Voltage Regulation of a Transmission Line should be _____? A. very high percentage. B. more than…
A: C. Zero or nil Option C is correct.
Q: mast-type service entrance
A: The service raceway according to NEC is defined as an enclosed channel specially designed to hold…
Q: How many conductor volume allowances should be applied for the equipment grounding conductors in the…
A: We need to answer how many conductor volume allowances should be applied for the equipment grounding…
Q: It is not possible to locate electrical equipment in less-hazardous areas, or in nonhazardous…
A: Hazardous sites are defined in electrical and safety engineering as places where there is a risk of…
Q: 8. How do the terms ‘impedance drop’, ‘voltage drop’ and ‘voltage regulation’, in connection of…
A: Impedance drop: Impedance drop is the product of the current and the internal impedance. The…
Q: Q.12 What provides branch-circuit protection, and where is it located? Select one: A. BREAKERS…
A: 12. A fuse is an electrical gadget used to shield the circuit from overcurrent. It comprises a…
Q: Where a building or structure is suplkied by more than one service, or a combination of branch…
A: By National Electrical Code (NEC), Article 225, there were a simple and fair way to install a…
Q: single-pole portable cable connectors for a portable switchboard on stage, where used, shall be…
A: single-pole portable cable connectors for a portable switchboard on stage, where used, shall be…
Q: Which of the following is a term missing from the National Electrical Code but used by manufacturers…
A: ANSWER (1) Grounding Triad is the term which is missing in NATIONAL…
Q: When a service is supplies by a grounded system, the ________ is required to be routed from the…
A: System is said to be grounded if it is connected to the earth by any conductive path inorder to…
Q: Which of the following is an installation requirement for the grounding electrode conductor in a…
A: ANSWER - (A,C,D) is correct EXPLANATION- Option (A)- Grounding…
Q: procedures
A: Explanation: The safety procedures and precautions to be taken when working with tools and…
Q: The point of attatchment of the service drop conductors to a building must not be less than ______…
A: The point of attachment of the service drop conductors to a building must not be less than 10 feet.…
Q: List the minimum service drop clearances required by the NEC in the following residential…
A: The minimum service drop clearance required by the NEC (120 V/240 V) for the following residential…
Q: | True
A: Sequence Local that is we pass a value from one sequence to the next
Q: Where insulated conductors are deflected within a wireway, either at the ends or where conduits,…
A:
Q: A ____shall be used to connect the equipment grounding conductors, the service equipment enclosures,…
A: Given, 3 multiple choice questions related to national electrical code.(NEC). Please find the below…
Q: The air interface connecting phones, antennas, and towers in mobile networks is completely devoid of…
A: Mobile Backhaul:- The transport network that links the mobile network's core network and RAN (Radio…
Q: Briefly discuss the loaded and non-loaded telephone cables
A: Loading is the process to increase inductance of line by adding lumped inductors atpredefined…
Q: When installing a surge arrester at the service of less than 1000 volts, the grounding conductor…
A: Equipment Grounding Conductor (EGC) – A conductive path that 's a component of a decent ground-fault…
Q: S. The general receptacle spacing requirements for all dwelling units are located in Section of the…
A: We are authorized to answer one question at a time, since you have not mentioned which question you…
Q: For residential wiring, not less than one 15-ampere lighting branch circuit should be provided for…
A: The National Electrical Code (NEC) is a regionally adoptable standard for the safe installation of…
Q: How many 14 AWG THHN conductors, including an equipment grounding conductor, can be installed in a…
A: Here we have to refer standard tables, When determining the maximum number of conductors permitted…
Q: The wording that I am running into with questions such as "The number of conductors required to be…
A: The number of conductors required to be installed between three-way and four-way switches is white…
Q: What size equipment grounding conductor is used with # 8 AWG nonmetallic-sheathed cable
A: The minimum size equipment grounding conductor is selected on the basis of the current rating…
The NEC requires the grounded conductors to be routed to the service disconnecting means enclosure and bonded to that enclosure. For equipment that is identified as suitable for use as service equipment, this is typically accomplished using a(n)________. a) Bonding conductor b) Grounding conductor c) Equipment grounding conductor d) Main bonding jumper
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
- 1.A. When a grounding electrode conductor is connected to the grounded conductor within a serviceequipment enclosure, it's required to be connected to the _______ terminal bus.A. service bonding jumperB. equipment groundingC. grounded conductorD. main bonding jumper1.B. The grounding electrode conductor for a DC system will have that conductor sized no smaller than_______ AWG aluminum.A. 8B. 6C. 10D. 121.C. What are the two key aspects of the installation of the grounding electrode conductor?A. Sizing and protectionB. Bonding and accessibilityC. Materials and placementD. Location and safety2.a. What's defined as an assembly consisting of a service raceway, guy wires or braces, service head, andany fittings necessary for the termination and support of overhead service conductors?A. Drip loopB. Service lateralC. Service dropD. Service mast 2.b. What's likely to happen when connected parallel conductors are different lengths?A. An NEC violationB. Misidentification of conductor cablesC. An uneven distribution of currentD. Conductor termination7.B. The size of a grounding electrode conductor for a service or separately derived system is generally basedon the size of the largestA. ungrounded supply conductor.B. equipment grounding conductor.C. grounded electrode.D. bonding jumper.7.C. Which of the following statements about bonding is true?A. The joint or termination must offer opposition in the circuit for effective electrical connections.B. Effective bonding keeps impedance high if a fault should occur.C. The entire electrical safety circuit is only as good as its strongest bonded link.D. Bonding connections must endure high levels of fault current until overcurrent protective devices can operate.
- 1. _______ is not considered an effective ground-fault current path. a) Ground b) Equipment grounding conductors c) Equipment bonding jumpers d) Grounded conductors 2.Which of the following is not a conductor in the grounding and bonding scheme for an ungrounded system? a) Grounding electrode conductor for grounding equipment enclosures and conductive parts b) Equipment grounding conductor c) Bonding conductors or jumper d) System grounded conductor1. Which of the following statements about equipment grounding conductors is true?A. Unacceptable equipment grounding conductors include conduit, tubing, and cable armor.B. They must be capable of withstanding the higher level of ground-fault current to perform their safety function.C. They increase voltages above ground potential on conductors and equipment enclosures during normal operation.D. When they're far from their associated circuit conductors, impedance values are kept as low as possible during ground-faultconditions.5. To interconnect grounding electrodes and form a grounding electrode system, connect the _______ to abusbar.A. bonding jumpers and their equipment grounding conductorsB. equipment grounding conductors and their neutral disconnect linkC. grounding electrode conductors and their bonding jumpersD. neutral disconnect links and their grounding electrode conductors
- 4. What can installation records be used to determine while servicing equipment?A. Broken connectors in a cable linkB. Problems due to aging during operationC. Broken fiberD. Decreased bending radius during operationA? Conductor is defined in NEC 240.2 as a conductor, other than a service conductor, having overcurrent protection ahead of its point of supply that exceeds the value permitted for similar conductors that are not taps. A. Faulted b. Tap c. Magnetic d. Copper-likeTo interconnect grounding electrode and form grounding electrode system, connect the________ to a busbar. A. Neutral Disconnect link and their grounding electrode conductor B. Grounding electrode conductor and their bond jumpers C. Bounding jumpers and their equipment grounding conductors D. Equipment grounding conductors and their neutral Disconnect link
- - Loads, Service, and Overcurrent Protection 6.a. The general lighting load is based on a _______ per square foot basis.A. kilowattB. number of circuitsC. volt-ampereD. general illumination6.b. What's the primary disadvantage of using copper conductors?A. AvailabilityB. WeightC. CostD. Durability11. Which of the following statements about the use of structural steel as an equipment grounding conductor (EGC) in an AC system is correct? A. Structural steel can be used as an EGC when it's bonded at both ends.B. Structural steel isn't allowed for use as an EGC.C. Structural steel must have an EGC bonding jumper every three feet of structure. D. Structural steel can be used as an EGC bonding jumper between panelboards. 12. Which of the following statements about equipment grounding conductors is true? A. They increase voltages above ground potential on conductors and equipment enclosures during normal operation. B. Unacceptable equipment grounding conductors include conduit, tubing, and cable armor. C. They must be capable of withstanding the higher level of ground-fault current to perform their safety function. D. When they're far from their associated circuit conductors, impedance values are kept as low as possible during ground-fault conditions. 13. Imagine that…A(n) _________ is a reliable conductor used to ensure the required electrical conductivity between metal parts required to be electrically connected. a) Equipment bonding jumper b) Bonding conductor of jumper c) Main bonding jumper d) Equipment grounding conductor