The insulation rating of class 3, PLTC, FPL, CM cables rated at ____ volts.
Q: 4. What terms describes an overcurrent protective device having an interrupting rating in compliance…
A: According to article 110.9 of the NEC, Circuit breaker describes an over-current protective device…
Q: Type UF cable, buried underground, fed from a 15-ampere, ground-fault circuit interrupter at a…
A: As stated by National Electric Code(NEC),the maximum cover of UF cable or the maximum burial depth…
Q: In the conduit layout shown in picture attached, determine how many wires are contained in each…
A: The circuit is shown below: Between the three-phase line and the disconnect switch. The switch is…
Q: If a 1 1/4-in. EMT raceway containing three conductors is already filled to 20%, what is the…
A: Need to find cross sectional area of raceaway
Q: 8. You've just completed a large structured cabling installation and notice that in a bundle of…
A: According to NEC (National electrical code) , in the installation of cable structure , unmarked and…
Q: Define cable rating in a built environment
A: Cable selection and application : It is essential to know cable construction, characteristics,…
Q: 11. What are at least two instances where a splice is allowed to be made in underground consumer's…
A: The power system has to transmit power from the generation side to the load side. For this purpose,…
Q: Identify and explain the safety procedures and precautions when working with tools and equipment's…
A: Electrical cables are used for transferring the signals and are also used for long distance…
Q: 8- Generally as of the operating voltage which of the following options are the correct words that…
A:
Q: What is the minimum branch circuit wire size that may be installed in a dwelling?
A: Basically, the 14 AWG wiring is used for typical lightening loads in the residence.
Q: Which of the following would help avoid the choke effect in grounding electrode conductors? A.…
A: The correct option is B that us using an appropriate PVC(POLY VINY CHLORIDE) CONDUIT WILL AVOID…
Q: 12. What is the conduit and wire equivalent to a 400A bus duct with both copper and aluminum?…
A: The National Electrical Code (NEC) is a collection of rules for the secure electrical wiring wiring…
Q: List the methods by which an equipment grounding conductor is connected to a device box
A:
Q: what is grading of cables, explain proper in details with block diagram
A: In a single-core cable, the conductor is surrounded by the dielectric material with an outer…
Q: A conductor with continuous white or gray covering shall be used only for the grounded circuit…
A: According to article NEC 200.6, the facts about the identification of the Grounded conductors are…
Q: How far can a 230V, 50A, three-phase load be located from a panelboard if it's fed with 3 AWG…
A: The Length of the load from the panel board is calculated as shown below
Q: Basically, ______receptacles are required to be installed if an equipment grounding conductor is…
A: Article 406 of NEC covers the installation of receptacles of both grounded type and non-grounded…
Q: Define line of support
A: The line support in terms of electrical energy is defined below: - The various kinds of structure…
Q: What type of bonding jumper connects the grounded circuit conductor and the equipment grounding…
A: In a power system , Main bonding jumper connects the grounded circuit conductor and the equipment…
Q: Explain the two main testing process used in testing transmission cables.
A: Fiber optics is a technology that is connected with the transmission of information as light rays…
Q: 6. Which of the following is a condition that a liquidtight flexible metal conduit must meet in…
A: Given :few mcqs on flexible metal conduit
Q: 8. How do the terms ‘impedance drop’, ‘voltage drop’ and ‘voltage regulation’, in connection of…
A: Impedance drop: Impedance drop is the product of the current and the internal impedance. The…
Q: Discuss Suspension insulators are recommended in high voltage transmission lines.
A: Pin encasings become excessively cumbersome an uneconomical past 33 kV. Thus, for voltages higher…
Q: 20. If a cable assembly such as a metal-clad (MC) cable includes an equipment grounding conductor…
A: given a mcq on optical cables and the coloured used for MC cables.
Q: In terminating the coaxial cable, If the present procedure is to loosen up the braided shield and…
A: In terminating the coaxial cable, the the flaring and bending back the outer braid onto the cable…
Q: single-pole portable cable connectors for a portable switchboard on stage, where used, shall be…
A: single-pole portable cable connectors for a portable switchboard on stage, where used, shall be…
Q: Identify and describe the step-by-step process used to install cable in the any building?
A: Step by step process to install cable in any buildings: step 1: In the slab, a PVC conduit is laid…
Q: Four No. 12 and four No. 10 conductors are to be installed in a EMT conduit. What size EMT conduit…
A: Conductors size is selected on the basis of assigned numbers. As the assigned number increases then…
Q: What range of leakage current must trip an IDCI?
A:
Q: Which of the following is a term missing from the National Electrical Code but used by manufacturers…
A: ANSWER (1) Grounding Triad is the term which is missing in NATIONAL…
Q: What is the type,application and rating of cables?
A: Types of cable are classified according to their Voltage level .
Q: . A grounded circuit conductor and the equipment grounding conductor should always be joined at the…
A: Choose the correct option A grounded circuit conductor and the equipment grounding conductor should…
Q: procedures
A: Explanation: The safety procedures and precautions to be taken when working with tools and…
Q: Which type of cable would you use to connect two buildings in an office installation? A. Buried…
A: Given & to find: Which type of cable would you use to connect two buildings in an office…
Q: Where insulated conductors are deflected within a wireway, either at the ends or where conduits,…
A:
Q: In the conduit diagram shown in attached picture, determine how many wires are in each conduit…
A: The circuit is shown below: Between the three-phase line and the disconnect switch. The switch is…
Q: Twenty-two 14 AWG copper conductors are run in conduit. Each conductor has type THHN insulation. the…
A: The given information is:
Q: What is grading of cables, explain.
A: Grading is defined as the process of equalizing the stress in the dielectric of the cable.…
Q: In terminating the coaxial cable, if the present procedure is to insert the BNC connector, length…
A: Important tools for making a coaxial cable: Compression tool Cable Stripper Compression Connectors…
Q: A? Conductor is defined in NEC 240.2 as a conductor, other than a service conductor, having…
A: The article 240.2 determine the current limiting of the over current protective device is used to…
Q: The contractor is controlled by?
A: According to the question we have to discuss the contractor is controlled by.
Q: A two conductor street main AB, 500 meters in length is fed from both end at 250 volts. Load of 50A,…
A: The solution can be achieved as follows.
Q: procedure for UG cable Joining?
A: It is asked to explain the procedure underground (UG) cable joining.
Q: Are double locknuts an acceptable bonding method for Class 1, Division 1 Hazardous locations? If…
A: Double locknuts are not totally acceptable bonding method for the class 1, division 1 hazardous…
Q: On a 120/240 V, single-phase, three-wire system, identify the following: a. Voltage between one…
A:
The insulation rating of class 3, PLTC, FPL, CM cables rated at ____ volts.
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
- 8. You're installing type AC cable. The armor coating of type AC cable is allowed for use as an equipmentgrounding conductor (EGC) because of itsA. liquid-tight fittings listed for EGC purposes.B. interlocking ribs that form a complete circuit.C. internal bare bonding strip.D. internal bare aluminum bonding conductor.11. Which of the following statements about the use of structural steel as an equipment grounding conductor (EGC) in an AC system is correct? A. Structural steel can be used as an EGC when it's bonded at both ends.B. Structural steel isn't allowed for use as an EGC.C. Structural steel must have an EGC bonding jumper every three feet of structure. D. Structural steel can be used as an EGC bonding jumper between panelboards. 12. Which of the following statements about equipment grounding conductors is true? A. They increase voltages above ground potential on conductors and equipment enclosures during normal operation. B. Unacceptable equipment grounding conductors include conduit, tubing, and cable armor. C. They must be capable of withstanding the higher level of ground-fault current to perform their safety function. D. When they're far from their associated circuit conductors, impedance values are kept as low as possible during ground-fault conditions. 13. Imagine that…3. Which of the following statements about the use of structural steel as an equipment grounding conductor(EGC) in an AC system is correct?A. Structural steel isn't allowed for use as an EGC.B. Structural steel can be used as an EGC bonding jumper between panelboards.C. Structural steel must have an EGC bonding jumper every three feet of structure.D. Structural steel can be used as an EGC when it's bonded at both ends.
- 11. Specific rules apply for the installation of _______, but no identification requirements for them exists.A. grounding electrode conductorsB. grounding electrodes.C. main bonding jumpers.D. equipment grounding conductors.19. What size copper bonding jumper must be used in an AC electrical system that has 500 kcmil copper phase conductors? A. 4/0 B. 1/0 C. 2/0 D. 3/0 20. A neutral disconnect link is usually in the form of a _______ in larger service equipment. A. screwB. wireC. clamp D. busbar3. The three bus-bar conductors in an outdoor sub-station are supplied by units ofpost insulators. Each unit consists of a stack of 3-pin insulators fixed one on the top of the other. The voltage across the lowest insulator is 8-45 kV and that across the next is 7-25 kV. Find the bus-bar voltage of the station. [38-8 kV]
- 1. Which of the following statements about equipment grounding conductors is true?A. Unacceptable equipment grounding conductors include conduit, tubing, and cable armor.B. They must be capable of withstanding the higher level of ground-fault current to perform their safety function.C. They increase voltages above ground potential on conductors and equipment enclosures during normal operation.D. When they're far from their associated circuit conductors, impedance values are kept as low as possible during ground-faultconditions.H2. A/An _______ is an insulating tube or sleeve that protects an electrical conductor where it passesthrough a hole.A. expansion fittingB. couplingC. gland nutD. bushing H3. Conductors that are larger than AWG size 8 will come only as a/an _______ conductor.A. aluminumEnd of examB. coveredC. solidD. stranded1.A. When a grounding electrode conductor is connected to the grounded conductor within a serviceequipment enclosure, it's required to be connected to the _______ terminal bus.A. service bonding jumperB. equipment groundingC. grounded conductorD. main bonding jumper1.B. The grounding electrode conductor for a DC system will have that conductor sized no smaller than_______ AWG aluminum.A. 8B. 6C. 10D. 121.C. What are the two key aspects of the installation of the grounding electrode conductor?A. Sizing and protectionB. Bonding and accessibilityC. Materials and placementD. Location and safety
- Define cable rating in a built environmentIf a grounding electrode conductor is connected at the first system disconnecting means or overcurrent device, the bonding jumper is sized the same as the ____. Select one: A. EQUIPMENT BONDING JUMPER B. POSITIVE CONDUCTOR C. SUPPLY-SIDE BONDING JUMPER D. NEUTRAL CONDUCTORa.2. Which of the following statements about grounding electrode conductors is true?A. They restrict the ground connection.B. They eliminate potential differences between conductive objects and the Earth electrode.C. They facilitate operation of overcurrent protective devices.D. They perform bonding between the Earth and grounded conductors.a.3. Main bonding jumpers are required to be made of _______ or other corrosion-resistant material.A. brassB. aluminumC. copperD. copper-clad aluminum