The input impedance of a particular commercial true rms multimeter can be considered to be the parallel combination of a resistance of 10x106 n and a capacitance of 100 pF. The multimeter is being used to measure the output voltage of a transducer with a 50 kHz sinusoidal output voltage. The Thevenin equivalent voltage and impedance of the transducer, relative to its output terminals, are 1 volt (rms) and 23.85 ko respectively. The Thevenin impedance may be assumed to be purely resistive. Which one is the correct statement? Select one: O a. The reading of the voltmeter will be 0.80 V O b. The reading of the voltmeter will be 1.0 V O c. The reading of the voltmeter will be 0.60 V O d. The reading of the voltmeter will be 0.57 V

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter21: Resistive-capacitive Series Circuits
Section: Chapter Questions
Problem 7RQ: An RC series circuit is connected to a 120-V, 60-Hz power source. The resistor is 25 and has a...
icon
Related questions
Question

please include working

The input impedance of a particular commercial true rms multimeter can be considered to
be the parallel combination of a resistance of 10x106 n and a capacitance of 100 pF. The
multimeter is being used to measure the output voltage of a transducer with a 50 kHz
sinusoidal output voltage. The Thevenin equivalent voltage and impedance of the
transducer, relative to its output terminals, are 1 volt (rms) and 23.85 kn respectively. The
Thevenin impedance may be assumed to be purely resistive.
Which one is the correct statement?
Select one:
O a. The reading of the voltmeter will be 0.80 V
O b. The reading of the voltmeter will be 1.0 V
O c. The reading of the voltmeter will be 0.60 V
O d. The reading of the voltmeter will be 0.57 V
Transcribed Image Text:The input impedance of a particular commercial true rms multimeter can be considered to be the parallel combination of a resistance of 10x106 n and a capacitance of 100 pF. The multimeter is being used to measure the output voltage of a transducer with a 50 kHz sinusoidal output voltage. The Thevenin equivalent voltage and impedance of the transducer, relative to its output terminals, are 1 volt (rms) and 23.85 kn respectively. The Thevenin impedance may be assumed to be purely resistive. Which one is the correct statement? Select one: O a. The reading of the voltmeter will be 0.80 V O b. The reading of the voltmeter will be 1.0 V O c. The reading of the voltmeter will be 0.60 V O d. The reading of the voltmeter will be 0.57 V
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Economic load dispatch
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning