Problem 7.56 Hot water at 50 °C is routed from one building in which it is generated to an adjoining building in which it is used for space heating. Transfer between the buildings occurs in a steel pipe ( k = 60W / m² K ) of 100-mm outside diameter and 8-mm wall thickness. During the winter, representative environmental conditions involve air at T, =-5 °C and V =3m/s in cross flow over the pipe. a) If the cost of producing the hot water is $0.10 per kW.h, what is the representative daily cost of heat loss from an uninsulated pipe to the air per meter of pipe length? The convection resistance associated with water flow in the pipe may be neglected. b) Determine the savings associated with application of a 10-mm-thick coating of urethane ( k=0.026 W / m.K ) to the outer surface of the pipe.

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter8: Natural Convection
Section: Chapter Questions
Problem 8.36P
icon
Related questions
Question
A Classwork for MENG420 - Heat Ti X
b My Tutoring | bartleby
+
classroom.google.com/u/1/w/MTQ3MTM5MDC2NTY3/t/all
C
E Apps M Gmail
YouTube
Translate
Маps
Given-Problems-MENG420-Chapter-7.pdf
Mount L
Open with ▼
Problem 7.56
Hot water at 50 °C is routed from one building in which it is generated to an adjoining building
in which it is used for space heating. Transfer between the buildings occurs in a steel pipe (
k = 60 W / m² .K) of 100-mm outside diameter and 8-mm wall thickness. During the winter,
representative environmental conditions involve air at T =-5 °C and V=3m/s in cross flow
over the pipe.
a) If the cost of producing the hot water is $0.10 per kW.h, what is the representative daily cost
of heat loss from an uninsulated pipe to the air per meter of pipe length? The convection
resistance associated with water flow in the pipe may be neglected.
b) Determine the savings associated with application of a 10-mm-thick coating of urethane (
k = 0.026 W /m.K ) to the outer surface of the pipe.
2 I 2
Q +
Page
9:02 PM
9 Classwork for MEN.
1 44) ENG
2/1/2021
...
Transcribed Image Text:A Classwork for MENG420 - Heat Ti X b My Tutoring | bartleby + classroom.google.com/u/1/w/MTQ3MTM5MDC2NTY3/t/all C E Apps M Gmail YouTube Translate Маps Given-Problems-MENG420-Chapter-7.pdf Mount L Open with ▼ Problem 7.56 Hot water at 50 °C is routed from one building in which it is generated to an adjoining building in which it is used for space heating. Transfer between the buildings occurs in a steel pipe ( k = 60 W / m² .K) of 100-mm outside diameter and 8-mm wall thickness. During the winter, representative environmental conditions involve air at T =-5 °C and V=3m/s in cross flow over the pipe. a) If the cost of producing the hot water is $0.10 per kW.h, what is the representative daily cost of heat loss from an uninsulated pipe to the air per meter of pipe length? The convection resistance associated with water flow in the pipe may be neglected. b) Determine the savings associated with application of a 10-mm-thick coating of urethane ( k = 0.026 W /m.K ) to the outer surface of the pipe. 2 I 2 Q + Page 9:02 PM 9 Classwork for MEN. 1 44) ENG 2/1/2021 ...
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 6 steps with 13 images

Blurred answer
Knowledge Booster
Convection
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning