Prob. No. 4-11 PD PL Length Section (kips) (kips) (ft) 175 26 W12 150 Steel A36 End Connection Two lines of 7/8-in Ø bolts (2 in a line 4 in on center) each flange Answer W12 X 58 LRFD W12 x 65 ASD

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
Select the lightest section for each of the situations described in the table. Assume that bolts are 3in on center. Do not consider block shear. Determine U from Table 3.2.
TABLE 3.2 Shear Lag Factors for Connections to Tension Members
Case
Description of Element
Shear Lag Factor, U
1
U = 1.0
2
All tension members where the tension
load is transmitted directly to each of the
cross-sectional elements by fasteners or
welds (except as in Cases 4,5 and 6).
All tension members, except plates and
HSS, where the tension load is transmitted
to some but not all of the cross-sectional
elements by fasteners or longitudinal
welds or by longitudinal welds in
combination with transverse welds.
(Alternatively, for W, M, S and HP, Case 7
may be used. For angles, Case 8 may be
used.)
U=1-x/l
U = 1.0
and
All tension members where the tension
load is transmitted only by transverse
welds to some but not all of the
cross-sectional elements.
A, area of the directly
connected elements
Plates where the tension load is
transmitted by longitudinal welds only.
Iz2w... U-1.0
2w>11.5w... U-0.87
1.5w >1zw...U-0.75
Round HSS with a single concentric
gusset plate
11.3D... U-1.0
D=1<1.3D... U-17
x = D/T
Rectangular HSS
with a single con-
12 H... U=1-X/1
centric gusset plate
B²+2BH
4(B+ H)
with two side gusset
plates
l=H… U-1-x
4(B + H)
W, M, S or HP
Shapes or Tees cut
from these shapes.
(If U is calculated
per Case 2, the
larger value is per-
mitted to be used.)
with flange con-
nected with 3 or
more fasteners per
line in the direction
of loading
by2/3d... U=0.90
by <2/3d... U=0.85
U= 0.70
with web connected
with 4 or more fas-
teners per line in the
direction of loading
with 4 or more fas-
teners per line in the
direction of loading
U=0.80
Single and double
angles (If U is
calculated per
Case 2, the larger
value is permitted to
be used.)
with 3 fasteners
per line in the
direction of loading
(With fewer than 3
fasteners per line in
the direction of
loading, use Case 2.)
U=0.60
/-length of connection, in. (mm); w plate width, in. (mm);
eccentricity of connection, in. (mm); B = overall
width of rectangular HSS member, measured 90° to the plane of the connection, in. (mm); Hoverall height of
rectangular HSS member, measured in the plane of the connection, in. (mm)
Source: AISC Specification, Table D3.1, p. 16.1-28, June 22, 2010. Copyright © American Institute
of Steel Construction. Reprinted with permission. All rights reserved.
3
4
5
7
8
Example
Ө
H
H
T
D
'я
Transcribed Image Text:TABLE 3.2 Shear Lag Factors for Connections to Tension Members Case Description of Element Shear Lag Factor, U 1 U = 1.0 2 All tension members where the tension load is transmitted directly to each of the cross-sectional elements by fasteners or welds (except as in Cases 4,5 and 6). All tension members, except plates and HSS, where the tension load is transmitted to some but not all of the cross-sectional elements by fasteners or longitudinal welds or by longitudinal welds in combination with transverse welds. (Alternatively, for W, M, S and HP, Case 7 may be used. For angles, Case 8 may be used.) U=1-x/l U = 1.0 and All tension members where the tension load is transmitted only by transverse welds to some but not all of the cross-sectional elements. A, area of the directly connected elements Plates where the tension load is transmitted by longitudinal welds only. Iz2w... U-1.0 2w>11.5w... U-0.87 1.5w >1zw...U-0.75 Round HSS with a single concentric gusset plate 11.3D... U-1.0 D=1<1.3D... U-17 x = D/T Rectangular HSS with a single con- 12 H... U=1-X/1 centric gusset plate B²+2BH 4(B+ H) with two side gusset plates l=H… U-1-x 4(B + H) W, M, S or HP Shapes or Tees cut from these shapes. (If U is calculated per Case 2, the larger value is per- mitted to be used.) with flange con- nected with 3 or more fasteners per line in the direction of loading by2/3d... U=0.90 by <2/3d... U=0.85 U= 0.70 with web connected with 4 or more fas- teners per line in the direction of loading with 4 or more fas- teners per line in the direction of loading U=0.80 Single and double angles (If U is calculated per Case 2, the larger value is permitted to be used.) with 3 fasteners per line in the direction of loading (With fewer than 3 fasteners per line in the direction of loading, use Case 2.) U=0.60 /-length of connection, in. (mm); w plate width, in. (mm); eccentricity of connection, in. (mm); B = overall width of rectangular HSS member, measured 90° to the plane of the connection, in. (mm); Hoverall height of rectangular HSS member, measured in the plane of the connection, in. (mm) Source: AISC Specification, Table D3.1, p. 16.1-28, June 22, 2010. Copyright © American Institute of Steel Construction. Reprinted with permission. All rights reserved. 3 4 5 7 8 Example Ө H H T D 'я
Prob.
No.
4-11
PD
PL
Length
Section (kips) (kips) (ft)
175
26
W12
150
Steel
A36
End Connection
Two lines of 7/8-in Ø bolts (2 in
a line 4 in on center) each flange
Answer
W12 X 58 LRFD
W12 x 65 ASD
Transcribed Image Text:Prob. No. 4-11 PD PL Length Section (kips) (kips) (ft) 175 26 W12 150 Steel A36 End Connection Two lines of 7/8-in Ø bolts (2 in a line 4 in on center) each flange Answer W12 X 58 LRFD W12 x 65 ASD
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Introduction to steel design
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning