In the analysis conducted with flame AAS, standard solutions of the X-type are analyzed individually and the absorbance values obtained are plotted against concentration (ppm). It was seen that the slope of the calibration line obtained was 0.0925. The standard deviation of the absorbance values obtained by reading the blank 10 times under the same conditions was calculated as 0.00183 ppm. According to this; For the X-type calculate the following: a) LOD b) LOQ c) Sensitivity
In the analysis conducted with flame AAS, standard solutions of the X-type are analyzed individually and the absorbance values obtained are plotted against concentration (ppm). It was seen that the slope of the calibration line obtained was 0.0925. The standard deviation of the absorbance values obtained by reading the blank 10 times under the same conditions was calculated as 0.00183 ppm. According to this; For the X-type calculate the following: a) LOD b) LOQ c) Sensitivity
Chapter16: Applications Of Neutralization Titrations
Section: Chapter Questions
Problem 16.17QAP
Related questions
Question
100%
In the analysis conducted with flame AAS, standard solutions of the X-type are analyzed individually and the absorbance values obtained are plotted against concentration (ppm). It was seen that the slope of the calibration line obtained was 0.0925. The standard deviation of the absorbance values obtained by reading the blank 10 times under the same conditions was calculated as 0.00183 ppm. According to this; For the X-type calculate the following:
a) LOD
b) LOQ
c) Sensitivity
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Recommended textbooks for you
Chemistry & Chemical Reactivity
Chemistry
ISBN:
9781337399074
Author:
John C. Kotz, Paul M. Treichel, John Townsend, David Treichel
Publisher:
Cengage Learning
Chemistry & Chemical Reactivity
Chemistry
ISBN:
9781133949640
Author:
John C. Kotz, Paul M. Treichel, John Townsend, David Treichel
Publisher:
Cengage Learning
Chemistry & Chemical Reactivity
Chemistry
ISBN:
9781337399074
Author:
John C. Kotz, Paul M. Treichel, John Townsend, David Treichel
Publisher:
Cengage Learning
Chemistry & Chemical Reactivity
Chemistry
ISBN:
9781133949640
Author:
John C. Kotz, Paul M. Treichel, John Townsend, David Treichel
Publisher:
Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning