In May 1970, a 70 ft tall, 20 ft diameter concrete grain silo was constructed at a site in EasternCanada (Bozozuk, 1972b). This cylindrical silo, which had a weight of 183 tons, was supportedon a 3 ft wide, 4 ft deep ring foundation. The outside diameter of this foundation was 23.6 ft,and its weight was about 54 tons. There was no structural floor (in other words, the contents ofthe silo rested directly on the ground).The silo was then filled with grain. The exact weight of this grain is not known, but wasprobably about 533 tons. Unfortunately, the silo collapsed on September 30, 1970 as a resultof a bearing capacity failure.The soils beneath the silo are primarily marine silty clays. Using an average undrainedshear strength of 500 lb/ft2 , a unit weight of 80 lb/ft3 , and a groundwater table 2 ft below the ground surface, compute the ASD factor of safety against a bearing capacity failure, then com-ment on the accuracy of the analysis, considering the fact that a failure did occur.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question

In May 1970, a 70 ft tall, 20 ft diameter concrete grain silo was constructed at a site in Eastern
Canada (Bozozuk, 1972b). This cylindrical silo, which had a weight of 183 tons, was supported
on a 3 ft wide, 4 ft deep ring foundation. The outside diameter of this foundation was 23.6 ft,
and its weight was about 54 tons. There was no structural floor (in other words, the contents of
the silo rested directly on the ground).
The silo was then filled with grain. The exact weight of this grain is not known, but was
probably about 533 tons. Unfortunately, the silo collapsed on September 30, 1970 as a result
of a bearing capacity failure.
The soils beneath the silo are primarily marine silty clays. Using an average undrained
shear strength of 500 lb/ft2

, a unit weight of 80 lb/ft3

, and a groundwater table 2 ft below the

ground surface, compute the ASD factor of safety against a bearing capacity failure, then com-
ment on the accuracy of the analysis, considering the fact that a failure did occur.

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Measuring concrete work
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning