For the circuit shown the RMS ratting current of the Thyristor =
Q: A 230V, 50 Hz supply is connected to a coil and series connected capacitor. Given X. = 33.52 and…
A:
Q: The RMS value of current, if the value of armature current is 11 A, a = 54 degrees, and B = 151…
A: The RMS value is the effective value value of varying quantity which dissipates same amount heat…
Q: A single phase circuit with a given load 3 ohm resistance and inductive reactance of 4 ohms as…
A: The question is about active power, reactive power and apparent power, power factor.
Q: The rotor resistance of the three phase induction motor is not affected by of the supply. If a…
A: 1)The rotor resistance of the three phase induction motor is not affected by PHASE SEQUENCE of the…
Q: For the circuit shown, a) To the coil of a henry, measure its internal resistance and the value of…
A:
Q: In capacitance, the length of the line is very large as compared with the distance of separation of…
A: Aim- To check whether the given statement is true or false . The statement-"In capacitance, the…
Q: Practical circuit diagram of the experiment OF NO-LOAD CHARACTERISTICS OF D.C. SHUNT GENERATOR…
A: The (Open Circuit Characteristic)O.C.C is a curve showing the relationship between the no-load emf…
Q: Derive and analyse relation of capacitance for 3 core cables.
A: Three core cables are those cables in which all the three line conductors are arranged in the lines…
Q: a. The value of excitation current required for full load current at 0.7 pf lagging (over-excited).…
A: The alternator is a machine which converts mechanical energy to electrical energy. It generates…
Q: What is the main direct cause of reactive power in AC system? A. Resistance of transmission lines B.…
A: The explanation is as follows.
Q: EMF method of determination of voltage regulation of an Alternator gives more value when compared to…
A: EMF method for the voltage regulation is also called as the synchronous impedance method and the MMF…
Q: A hydro generator on the Jordan Valley has a rating of 1 MW, 1000 rpm. Then, the number of rotor's…
A: Given: A hydro generator in Jordon valley has a rating of 1 MW , 1000 RPM . To find the number of…
Q: R = 2 kN E = 282 sen (100at) 40 L =- H r = 2 kN 10 C =- µF
A:
Q: 7- Draw a curve represented the relation between the inductive reactance as (y- axis) and the…
A: As this question is missing the data , so it will be difficult to solve 4,5 & 6 question. Here I…
Q: The resistance and inductance of a coil can be obtained by connecting the coil in series with a…
A:
Q: 11. A utility company plans to connect a total of 20 µ.F of capacitance to a 7200-V line. To make…
A: Whenever we connect the capacitors in series the then equivalent capacitance will decrease Let us…
Q: Example 10.7. The inductance of attraction type instrument is given by L = (10+50-0²)µH where is the…
A: Given, Inductance of attraction type instrument, L=10+5θ-θ2 μH θ is the deflection in radian from…
Q: The mutual inductnce between two unity coupled coils of 9 H and 4 H will be ?
A: Given: Coil 1 inductance, L1 = 9 H Coil 2 inductance, L2 = 4 H As coil is unity coupled, so…
Q: A sinusoidal voltage with maximum value (336 V), and a Frequency its value (50 Hz), was applied on a…
A:
Q: Manufacturers usually specify the impedances of machines and transformers in O Percent O Per-unit O…
A: Need to Find correct option
Q: resistance of 20 Ω, an inductance of 0.2H and a capacitance of 100μF are connected in series across…
A: In this question , series RLC circuit is given....We have to find out impedance , current , voltage…
Q: Example 7:The capacitances of a 3-phase belted cable are 12-6 µF between the three cores bunched…
A: The solution is given below
Q: A single phase circuit with a given load 5 ohm resistance and capacitive reactance of 2 ohms as…
A:
Q: Vs 18 V pk RL 220 N (a)
A:
Q: Calculate the phase shifts, de(k), for the hard core potential, V(r) 00, r a. %3D Simplify the…
A: For the hardcore potenctial, V(r) = ∞r<a0r<a Here, we have to simplify for the S-wave.
Q: 2. calculate the n at 25% , 50% , 75% , 100% and 125% full load condition for u.p.f and 0.8 p.f lag…
A:
Q: Transform 4A to independent voltage source and then determine the voltage drop at 2ohms
A: According to the question, we need to find the voltage drop across 2 Ω resistor by using current…
Q: 2. Mention five (5) factors determining the size and direction of the generated emf.
A: Factors which is considered to determine the size and direction of EMF
Q: HW In the chopper circuit shown, E = 220U, L = 1.5mH R = 0.5 and it is operating with T=3ms and Ton…
A: Given data, The supply voltage (E)= 220V The given inductance(L) = 1.5mH The value of resistance (R)…
Q: A coil has a resistance of 50 ohms and an inductance of 0.5 Henry. What is the RMS value of current…
A: In this question, A coil has a resistance R= 50 ohms And inductance L=0.5 Henry. What is the RMS…
Q: The phase angle between magnetizing component current and core loss component current is 90° Select…
A:
Q: Units SI Nominal power and frequency [Pn(VA) fn(Hz)]: 250e6 50 ] Winding 1 parameters [V1(Vrms)…
A: Given data,
Q: An impedance coil having a resistance of 15 ohms and an inductance of 0.08 henry is connected in…
A: Given -: All the resistance, inductance & capacitance are connected in series hence the same…
Q: A single-phase motor takes 10A at a power factor of 0.7 lagging when connected to a 230V, 50 Hz…
A: Given: Power factor of the motor cosϕ=0.7 (lag), ϕ=-45.57°. Terminal voltage of the motor Vt=230∠0°…
Q: A 50 Hz, 11KV, 3-ph, alternator with earthed neutral has a reactance of 5 Ω\ ph and is connected to…
A:
Q: (A) The capacitances of a 3-phase belted cable are 12-6 µF between the three cores bunched together…
A: Consider the given below diagram of the cable,
Q: 2. The synchronous reactance of a three-phase, star connected, 380 V, 50 Hz, cylindrical alternator…
A: Note: We are authorized to answer three subparts at a time since you have not mentioned which part…
Q: Q4. Define three cases on which real and reactive power flow gets affected. Draw the phasor diagrams…
A: Active power- The power is utilized or consumed in an AC circuit. It is known as real power, True…
Q: Q2) A generating station has a maximum demand of 30 MW, a loac and plant use factor of 0.8.…
A: According to question:
Q: pasic requirement psed one wind; ave winding o: ar (h) or (o)
A: The DC motor convert an electrical energy into mechanical energy. The following Dc motor are used in…
Q: e reactive power output of a mited by load angle True
A: In this question , we have to explain that which quantity limits reactive power output of an…
Q: Which the following parameters are considered for analysis of AC distribution system? O a.…
A: In ac we need to analyse active and reactive power consumption by the distribution system, and we…
Q: 2. A 400-V, 3-phase induction motor load takes 900 kVA at a power factor of 0.707. Calculate the kVA…
A: Case I S= 900 KVA PF1= 0.707 PF1 = cos ϕ1 = 0.707 Φ1= 45° Real power P1 = S * PF1 = 900k * 0.707 =…
Q: Three identical capacitors of 10 micro farad are connected in delta across a 415 volts, 50HZ,…
A:
Q: In the chopper circuit shown in figure below, E=220 V, L= 1.5 mH, R=0.5 ohm and it is operating with…
A:
Q: Generate a conclusion on this following statements: Determine and analyze the voltage regulation…
A: GIVEN: resistive load inductive load capacitive load DETERMINE: the…
Q: 3-phase induction motor load takes 900 kVA at a power factor of 0.707. Calculate the KVA rating of…
A: Given data: KVA Rating, S=900 kVAInitial Power factor cos ϕ1=0.707ϕ1=cos-10.707=450
Q: 3. If the ratio of V/F has been kept constant and the observed value of hysteresis loss at ra…
A:
Q: A single phase motor connected to 400V, 50HZ supply takes 37A at a power factor of 0.8 lagging.…
A: The power system has to transmit power from the generation side to the load side. For this purpose,…
Q: QUESTION 55 "Since most loads are capacitive in nature (e.g. motors), improvement of power factor is…
A: In this question choose the correct option Check the given Statment is true or false?
Step by step
Solved in 2 steps with 2 images
- A elearning.adpoly.ac.ae * Question Completion Status: QUESTION 16 E-06, PC-02. Three inductors 15 mH, 15 mH and 15 mH are connected in parallel. What is the total inductance? O Without knowing the coupling factor the total inductance cannot be found. O 45mH. O5 mH. QUESTION 17 E-06, PC-04. The time constant in an inductive circuit is the time required for the current to reach? O 70.7% of maximum value. O 63,7% of maximum value. O 63,2% of maximum value. QUESTION 18 E-06, PC-01. When more than two inductors of different inductance are connected in parallel in a circuit, the total inductance is? O Less than the inductance of the lowest rated inductor. O Equal to the sum of the individual inductance. O Equal to the inductance of the highest rated inductor. QUESTION 19 E-06, PC-02, Three inductors 15 mH, 15 mH and 15 mH are connected in series, What is the total inductance? Click Saue and Submit to save and submit. Click Save All Answers to save all answers.Calibri (Body) -11 by AaBbCcDx AaBbCcD AaBbC AaBbCc AaB AaBbCc. mat Painter BIU 1Normal 1No Spaci. Heading 1 Heading 2 Title Subtitle Chang Styles d Font Paragraph Styles IMPEDANCE QUIZ # 2 1. What capacitance when connected in series with a 500Q resistor will limit the current drawn from a 48-mV 465-kHz source to 20µA? * a. 144pF b. 145pF c. 146pF d. 147pF MY ANSWER: c.146pF 2. What is the total impedance at 20kHz of a series circuit consisting of a 1.5mH inductance, a 100Q resistance, and a 0.08uF capacitance? * a. 1340 41.7 b. 1930 L-37.2" C. 920 290 d. 530 2-12.6°n 12 For the given waveforms, waveform D the waveform E. put of -D uestion Degrees 30 60 90 180 210 360 N. In a step down transformer, number of turns in the primary winding is lesser than the number of turns in the secondary winding. Select one: O True en O False nere to search
- A supply of 240V-50HZ feeds a highly inductive load of 502 through thyristor bridge that is half-controlled. What is the load power factor when the firing angle delay is 45°? A. 0.6565 B. 0.5566 C. 0.6655 D. 0.5656 1igatioOhmic components have a V-I curve O Non-linear VI curve. Parabolic VI curve. Sinusoidal VI curve. Straight line VI curve.the shunt capacitance is a capacitor O a. Between a phase and the ground O b. between phases and a phase to ground c. none of the answers O d. Between phases
- 6. What is the effect of load inductance on the ripple current? 7. i effect of chonnine Bock and boost 8. Wh 9 What chopping 10. At what duty evcle does the load current rinnle current heThe average value of sinusoidal varying voltage is more than its r.m.s. value. Select one: O True O False Which of the following formula is CORRECT? a. E= - L d0/dt O b. E = - N dl/dt O . L= NI / O O d. W = 0.5 12L In a step down transformer, number of turns in the primary winding is lesser than the number of turns in the secondary winding. Select one: O True O FalseBy convention, the sign of reactive power to an inductance is and the sign of reactive power to a capacitance is
- For the circuit shown the RMS ratting current of the Thyristor= Firring angle-40Degree phasel-120sinwt Vo 20 Ohm O 4.5A O 4.6A O 2.6A O 1.6A O 2.5A O 3.6A O 1.SA 3.5AValue of series impedance if inductance is 5mH , resistance is 4 ohm and frequency is 50 Hz.Calculatethe Value of the Capaeitance at resanamce if w-SooD rad/Seea.k or6 齐