Electricity can be a hazard in hospitals, particularly to patients who are connected to electrodes, such as an ECG. Suppose that the motor of a motorized bed shorts out to the bed frame, and the bed frame's connection to a ground has broken (or was not there in the first place). If a nurse touches the bed and the patient at the same time, the nurse becomes a conductor and a complete circuit can be made through the patient to ground through the ECG apparatus. This is shown schematically in Fig. 19–75. Calculate the current through the patient. Bed ww (low R) Patient wo 104 2 Nurse 104 2 ECG - apparatus (low R) 1042 |Motor 240 V FIGURE 19–75 Problem 70.

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter29: Dc Generators
Section: Chapter Questions
Problem 1PA: You are working as an electrician in a large steel manufacturing plant, and you are in the process...
icon
Related questions
Question
Electricity can be a hazard in hospitals, particularly to
patients who are connected to electrodes, such as an ECG.
Suppose that the motor of a motorized bed shorts out to the
bed frame, and the bed frame's connection to a ground has
broken (or was not there in the first place). If a nurse touches
the bed and the patient at the same time, the nurse becomes
a conductor and a complete circuit can be made through the
patient to ground through the ECG apparatus. This is shown
schematically in Fig. 19–75. Calculate the current through the
patient.
Bed
ww
(low R)
Patient
wo
104 2
Nurse
104 2
ECG
- apparatus
(low R)
1042
|Motor
240 V
FIGURE 19–75 Problem 70.
Transcribed Image Text:Electricity can be a hazard in hospitals, particularly to patients who are connected to electrodes, such as an ECG. Suppose that the motor of a motorized bed shorts out to the bed frame, and the bed frame's connection to a ground has broken (or was not there in the first place). If a nurse touches the bed and the patient at the same time, the nurse becomes a conductor and a complete circuit can be made through the patient to ground through the ECG apparatus. This is shown schematically in Fig. 19–75. Calculate the current through the patient. Bed ww (low R) Patient wo 104 2 Nurse 104 2 ECG - apparatus (low R) 1042 |Motor 240 V FIGURE 19–75 Problem 70.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer