Calculate the service tensile load capacity for an angle bar L 125 x 75 x 12 A53 steel connected with 13 A490 bolts as shown in the Figure 2. Diameter of holes is 3mm larger than the bolt diameter. Bolt diameter = 13 mm Standard hole = 24 mm Use hole diameter = 13 + 3 = 16 mm a = 43.5 mm b = 51 mm c = 36 mm d = 252 mm
Calculate the service tensile load capacity for an angle bar L 125 x 75 x 12 A53 steel connected with 13 A490 bolts as shown in the Figure 2. Diameter of holes is 3mm larger than the bolt diameter. Bolt diameter = 13 mm Standard hole = 24 mm Use hole diameter = 13 + 3 = 16 mm a = 43.5 mm b = 51 mm c = 36 mm d = 252 mm
Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN:9781337094740
Author:Segui, William T.
Publisher:Segui, William T.
Chapter9: Composite Construction
Section: Chapter Questions
Problem 9.8.6P
Related questions
Question
Calculate the service tensile load capacity for an angle bar L 125 x 75 x 12 A53 steel
connected with 13 A490 bolts as shown in the Figure 2. Diameter of holes is 3mm larger than
the bolt diameter.
Bolt diameter = 13 mm
Standard hole = 24 mm
Use hole diameter = 13 + 3 = 16 mm
a = 43.5 mm
b = 51 mm
c = 36 mm
d = 252 mm
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 2 steps with 2 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Steel Design (Activate Learning with these NEW ti…
Civil Engineering
ISBN:
9781337094740
Author:
Segui, William T.
Publisher:
Cengage Learning
Steel Design (Activate Learning with these NEW ti…
Civil Engineering
ISBN:
9781337094740
Author:
Segui, William T.
Publisher:
Cengage Learning