Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN: 9780133923605
Author: Robert L. Boylestad
Publisher: PEARSON
expand_more
expand_more
format_list_bulleted
Question
6. According to the NEC, allowance for the future expansion of installations is
A. an exception.
B. in everyone's best interest.
C. defined.
D. a requirement.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution
Trending nowThis is a popular solution!
Step by stepSolved in 2 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 20.a. What's the primary disadvantage of using copper conductors?A. DurabilityB. CostC. AvailabilityD. Weight20.b. The NEC requires that each service-disconnecting means be suitable forA. hazardous locations.B. disconnecting the meter.C. wet conditions.D. the prevailing conditions 20.c. As a general rule, each building or structure is limited to a single service. What's an automatic exceptionto this rule?A. A second service deemed suitable for useB. A second service having the proper markingsC. Emergency systems or fire pumpsD. Higher building occupancyarrow_forward5. Electrical apprentices must take _______ core hours of training to satisfy the Michigan academic program requirement. A. 650 B. 550 C. 250 D. 450arrow_forward16. Flexible metal conduit will be installed between a raceway and a transformer in a system. If it's to serve as an equipment grounding conductor, the flexible conduit and its fittings must be less than _______ feet. A. 2 B. 6 C. 10 D. 4 17. In which of the following situations can an equipment ground conductor be run separately from the circuit conductors? A. When you install a GFCI and are connecting additional receptaclesB. When the connection is to be made to a nearby water pipeC. When you're replacing an ungrounded two-wire receptacle with a grounded receptacle D. When there are no spare conductors in the cable 18. A 400-amp circuit breaker protects a feeder that's installed in a nonmetallic raceway that requires an equipment grounding conductor. Which of the following is the minimum size of aluminum equipment grounding conductor that should be used in this situation? A. No. 4B. No. 1C. No. 6 D. No. 2 19. Which of the following is bonded to the grounding electrode system…arrow_forward
- The term "____" is defined in NEC® Article 100 as "connected to establish electrical continuity and conductivity." Select one: A. BENDED (BENDING) B. BONDED (BONDING) C. SHUNTED (SHUNTING) D. GROUNDED (GROUNDING)arrow_forwardA? Conductor is defined in NEC 240.2 as a conductor, other than a service conductor, having overcurrent protection ahead of its point of supply that exceeds the value permitted for similar conductors that are not taps. A. Faulted b. Tap c. Magnetic d. Copper-likearrow_forward1. The only exception to the need for all information technology equipment to be satisfactorily grounded is where the equipment is A. DC powered.B. backup generator powered. C. double-insulated.D. isolated equipment. 2. Which section of the National Electrical Code lists sizing requirements for wire-type equipment grounding conductors? A. 250.66 B. 250.118 C. 250.4 D. 250.122 3. Which of the following statements about grounding electrical equipment is true?A. If no wire-type equipment grounding conductors are present with the branch circuits, the equipment grounding terminal bar isn't required.B. Grounding electrical equipment increases the possibility of metal parts remaining energized.C. The nonmetal parts of some electrical equipment are required to be connected to an equipment grounding conductor. D. Equipment grounding conductors can be spliced together outside of a grounded metal box. 4. Which of the following is a condition that must be met in order to qualify for the exemption…arrow_forward
- 4 Describe the various methods of laying underground cables. What are the relative advantages anddisadvantages of each method?arrow_forward6.a. The amount of short-circuit current that flows depends upon the amperes available at the source ofpower, the length of the circuit, and what other primary factor?A. The presence of a ground fault currentB. Proper installation of the branch circuitC. Presence of no previous damage to the electrical systemD. The size of the conductors and voltage at which they operate6.b. You're evaluating the components of a multioccupancy building that won't have an on-site employee. Tobe compliant with the NEC, each occupant will need to have access to their ownA. service-disconnecting means.B. service conductor.C. cable attachment point.D. emergency fire water-pump disconnect.arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,