Underground service conductors shall have [Fill-in-the-blank].
A)adequate mechanical strength.
B)sufficient ampacity for the loads calculated.
C)none of these.
D)adequate mechanical strength and sufficient ampacity for the loads calculated.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution
Trending nowThis is a popular solution!
Step by stepSolved in 2 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 4.a. Which of the following maintenance practices should be carried out most frequently on motive-powerbatteries?A. Replacing cable insulationB. Replacing the vent capsC. Checking the specific gravity of the electrolyteD. Checking the electrolyte level4.b. During the formation of a lead-acid battery, which of the following takes place?A. The active materials in the negative plate are converted to lead dioxide.B. Lead sponge in the negative plate is converted to lead sulfate.C. Lead sulfate in the positive plate is converted to lead dioxide.D. The active materials in the positive plate are converted to lead sulfate.arrow_forwardThere are two images, please answer parts a, b, and c and label them.arrow_forward"Electrical machines/ I need a complete and clear solution for all sub -questions of a single question. Thank you."arrow_forward
- b) A fault occurs at bus 3 of the network shown in Figure Q4. Pre-fault nodal voltages throughout the network are of 1 p.u. and the impedance of the electric arc is neglected. Sequence impedance parameters of the generator, transmission lines, transformer and load are given in Figure Q4. V₁ = 120° p.u. V₂ = 120° p.u. V₂ = 1/0° p.u. V₂= 120° p.u. jXj0.1 p.u. JX2) 0.1 p.u. jX0j0.15 p.u. jXn-j0.2 p.u. 1 JX(2)-j0.2 p.u. 2 jX)=j0.25 p.u. JX20-10.15 p.u. jXa(z)-j0.2 p.u. 4 jX2(0)=j0.2 p.u. jXT(1) j0.1 p.u. jXT(2)=j0.15 p.u. jXT(0)=j0.1 p.u. Figure Q4. Circuit for problem 4b). = jXj0.1 p.u. j0.1 p.u. - JX(2) JXL(0) 10.1 p.u. = (i) Assuming a balanced excitation, draw the positive, negative and zero sequence Thévenin equivalent circuits as seen from bus 3. (ii) Determine the positive sequence fault current for the case when a three- phase-to-ground fault occurs at bus 3 of the network. (iii) Determine the short-circuit fault current for the case when a one-phase- to-ground fault occurs at bus…arrow_forwardA cable is tested by loss of charge Method using a Ballistic galvanometer with following results : Discharged immediately after electrification deflection 200 divisions. Discharged after 30 second and after electrification (i) Deflection 126 divisions (ii) When in parallel with a resistance of 10 V deflection 100 divisions. Calculate the insulation resistance of the cable.arrow_forwardCalculate the number of turns and the cross section of a conductor for a 300 kVA, 66000/400 volts, 50 Hz, single pahse core type transformer use 1.6 A/mm^2 as current density, 0.070 Wb as maximum flux.arrow_forward
- G1=2 G2=4 G3=2 G4=7 G5=2 G6=1 G7=2arrow_forwardThe voltage drop percentage for a panel feeder with a no continuous load of 180A, using 3/0 THWN copper conductors at 480V, three-phase, and a length of 248' isarrow_forward3.a. There may be installations where grounded conductors of different systems are installed within the sameraceway, cable, or box. In these cases, it's imperative that the system-grounded conductors remainA. spliced.B. disconnected.C. separated.D. buried.3.b. In dwelling units, the maximum allowable voltage between conductors that supply lighting fixtures isA. 220 V.B. 120 V.C. 115 V.D. 110 V.arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,