A W 5300*101 of Steel Section (fy= 345 MPa & fu= 450 MPa) is used as simply supported beam with a span of 15 m. The dead load is the summation of the super dead load (7 kN/m as uniform load) and the beam weight. In addition to the dead load, a uniform live load is applied to the beam. If the lateral support is provided at 3-meter intervals, what is the maximum service live load in kN/m that can be supported.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question

kindly solve this question|?

A W 5300*101 of Steel Section (fy= 345 MPa & fu= 450 MPa) is used as simply supported beam
with a span of 15 m. The dead load is the summation of the super dead load (7 kN/m as uniform
load) and the beam weight. In addition to the dead load, a uniform live load is applied to the beam.
If the lateral support is provided at 3-meter intervals, what is the maximum service live load in
kN/m that can be supported.

1- A W 5300*101 of Steel Section (f,= 345 MPa & fu= 450 MPa) is used as simply supported beam
with a span of 15 m. The dead load is the summation of the super dead load (X1 kN/m as uniform
load) and the beam weight. In addition to the dead load, a uniform live load is applied to the beam.
If the lateral support is provided at 3-meter intervals, what is the maximum service live load in
kN/m that can be supported.
About X-X
About Y-Y
Flange
Flange
Web
Mass
Area
Depth
S
Width
thickness
thickness
(kg/m)
I (10)
(10)
(mm2)
(mm)
(10°) (10)
(mm)
(mm)
(mm)
mm
(mm)
(mm)
mm
mm
mm
W530*101
101
12900
536
210
17.4
10.9
616
2290
218
26.9
257
45.7
Transcribed Image Text:1- A W 5300*101 of Steel Section (f,= 345 MPa & fu= 450 MPa) is used as simply supported beam with a span of 15 m. The dead load is the summation of the super dead load (X1 kN/m as uniform load) and the beam weight. In addition to the dead load, a uniform live load is applied to the beam. If the lateral support is provided at 3-meter intervals, what is the maximum service live load in kN/m that can be supported. About X-X About Y-Y Flange Flange Web Mass Area Depth S Width thickness thickness (kg/m) I (10) (10) (mm2) (mm) (10°) (10) (mm) (mm) (mm) mm (mm) (mm) mm mm mm W530*101 101 12900 536 210 17.4 10.9 616 2290 218 26.9 257 45.7
Expert Solution
steps

Step by step

Solved in 5 steps

Blurred answer
Knowledge Booster
Design criteria for structural loading
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning