A thermocouple is connected to a data acquisition system which is used to measure temperature of air in a duct. For a step-input, the system measures the temperature accurately at steady state. Assume the dynamics of the sensor(thermocouple) limit the system's speed of response. The sensor has a time constant of 0.5 sec. In a given situation, the duct's air temperature varies with time as a sinusoid of frequency 2 rad/s with amplitude of 10°C. In this case, the measured temperature by the system is a sinusoid as well, as a function of time. The amplitude of this (measured) sinusoid, at steady-state, is closest to: Select one: а. 10°с O b. 5°C C. 3°C d. 7°C

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
icon
Concept explainers
Question
A thermocouple is connected to a data acquisition system which is used to measure temperature of air
in a duct. For a step-input, the system measures the temperature accurately at steady state. Assume the
dynamics of the sensor(thermocouple) limit the system's speed of response. The sensor has a time
constant of 0.5 sec. In a given situation, the duct's air temperature varies with time as a sinusoid of
frequency 2 rad/s with amplitude of 10°C. In this case, the measured temperature by the system is a
sinusoid as wellI, as a function of time. The amplitude of this (measured) sinusoid, at steady-state, is
closest to:
Select one:
а.
10°C
b. 5°C
С.
3°C
O d. 7°C
Transcribed Image Text:A thermocouple is connected to a data acquisition system which is used to measure temperature of air in a duct. For a step-input, the system measures the temperature accurately at steady state. Assume the dynamics of the sensor(thermocouple) limit the system's speed of response. The sensor has a time constant of 0.5 sec. In a given situation, the duct's air temperature varies with time as a sinusoid of frequency 2 rad/s with amplitude of 10°C. In this case, the measured temperature by the system is a sinusoid as wellI, as a function of time. The amplitude of this (measured) sinusoid, at steady-state, is closest to: Select one: а. 10°C b. 5°C С. 3°C O d. 7°C
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Chemical and Phase Equilibrium
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY