Transcribed Image Text:A single phase has two group of conductors A & B; where A consists of 3- sub conductors (a, b, c) each of
its have a radius of 0.25 cm, and the group B consists of two sub conductors (d, e) each of its have a radius
of 0.5 cm. Calculate the inductance of the total system where the distance between the sub conductors is as
below.
9m
6m
6m
୦୩
Group A
Group B
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 2 steps with 1 images

Knowledge Booster
Similar questions
- Help me i need answer in 30 minutes please please please please In a 10 km long three phase conductor diameter of 2.5 mm the conductors are arranged symmetrically with a spacing of 2 m. So find per phase inductance.arrow_forwardWhat is the capacitance per kilometer per phase of a single circuit, two bundle conductor line with horizontal configuration? The distance between the bundled conductors is 30 cm and the diameter of each conductor is 5cm. The distance between the centers of the bundle is 5mChoices: 0.0132uF/km 0.0126 uF/km 0.0143uf/km 0.0116uF/km Please in typing format pleasearrow_forwardCalculate the inductance of the single-phase double circuit line shown in the figure, the diameter of each conductor is .2 cm d=2 cm 100 cm 100 cm-arrow_forward
- The ACSR conductor Falcon is used in a 3-phase equidistant configuration with D = 42 feet. The per kilo feet inductive reactance will be: O A. 0.1537 B. 0.8117 O C. 0.1475 O D. 0.1148 O E. None of choices are correctarrow_forwardA single phase has two group A and B, 50 Hz, overhead line system has radius of conductor 0.5 cm. alculate the total inductance of the line. a2 a1 6 cm 2 m 3m b₂ m B b₁arrow_forwardA 33 kV, 50 Hz. 3-phase underground cable, 6 km long uses three single core cables. Each of the conductor has a diameter of 2.75 cm and the radial thickness of insulation is 0.4 cm. Determine (1) capacitance of the cable/phase (ii) charging current/phase (iii) total charging KVAR. The relative permittivity of insulation is 3.arrow_forward
- Task 3 A three phase, four wire star connected load consisting of: ZR: a resistor of 9500 in series with a 3H inductor ZB: a resistor of 1950 ZY: a resistor of 1950 in series with a 4µF capacitor Using the equipment available in the power lab (Room T017), connect the given load to a three-phase supply available in the lab and: 3.1. Determine the current of each line and the neutral current and measure the total power supplied by the source. 3.2. Analytically, calculate all currents and the total power and compare with those obtained in measurements. 3.3. Device a method and measure the waveform of the neutral current. Discuss the obtained waveform and the reason for any distortion in the waveform 3.4. Validate your calculations using computer simulationarrow_forwardProvide correct details solution Full complete questionarrow_forward3. Find the capacitance per unit length of the single-phase line shown below. Conductors a, b, c are of 0.2 cm radius, and conductors d and e are of 0.4 cm radius. Oa 4m Oe 6ide X Side Yarrow_forward
- 1- A single phase line has two parallel conductors 3m apart. The radius of each conductor is 1.2 cm. calculate the loop inductance per km of the line. 2- A single phase line has two parallel conductors 4m apart. The radius of each conductor is 2m. Calculate the capacitance per km of the line.arrow_forward15) Kirchhoff's Voltage Law (KVL) states that A) the product of the phasor voltages around any closed path must equal zero. B) the sum of the phasor voltages around any closed path does not have to equal zero. C) the sum of the phasor voltages around any closed path must equal zero. D) the sum of the phasor voltages around a closed path cannot include "through the air."arrow_forwardRedo it again with full details..arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage LearningDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage Learning
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT


Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning

Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning

EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT