A single line diagram of a power system is shown in Fig.3.1. All the sequence reactances of the power system components are depicted in per unit on 20 MVA base, 110KV (L-L) in transmission circuit. If a single line to ground fault occurs on phase a through a reactance of 150 ohm at F, determine the current in ampere fed into the fault. The fault point F is assumed to be at 65% of transmission line length from the bus bar connected to generators A and B. 20 MVA A X,-j0.3 X;-j0.3 X-j0.05/ |X-X-j0.1 Xp-j 0.35 II KV C 110 KV 20 MVA X-X-XJ 0.1 X,-j0.25 X;-j0.25 X-j0.05 Transmission circuit D XXj0.1 Xj 0.S X-X-Xj 0.1

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
100%
3G, 4G.
4G2 54
il ii 12:28
Edit
50
Assignment
Week 7
[CLO 1, PLO 1, C3]
Statement
A single line diagram of a power system is shown in Fig.3.1. All the
sequence reactances of the power system components are depicted in per
unit on 20 MVA base, 110KV (L-L) in transmission circuit. If a single line
to ground fault occurs on phase a through a reactance of 150 ohm at F,
determine the current in ampere fed into the fault. The fault point F is
assumed to be at 65% of transmission line length from the bus bar
connected to generators A and B.
20 MVA
X;=j0.3
Xj0.3
X-j0.05/ X-X,=Xj 0.1
A.
x-X,- j0.1 Xrj 0.35
nm 11 KV
20 MVA
X,-j0.25
X3=j0.25
Xj0.05
110 KV
Transmission
X-X;-Xg=J 0.1
circuit
Y
B
FS
D
X-X-j0.1 X-j 0.35
X-X-X;-j 0.1
X-X-X-J 0.1
End :
DO
פם
Tools
Mobile View
Share
Edit on PC
School Tools
88
Transcribed Image Text:3G, 4G. 4G2 54 il ii 12:28 Edit 50 Assignment Week 7 [CLO 1, PLO 1, C3] Statement A single line diagram of a power system is shown in Fig.3.1. All the sequence reactances of the power system components are depicted in per unit on 20 MVA base, 110KV (L-L) in transmission circuit. If a single line to ground fault occurs on phase a through a reactance of 150 ohm at F, determine the current in ampere fed into the fault. The fault point F is assumed to be at 65% of transmission line length from the bus bar connected to generators A and B. 20 MVA X;=j0.3 Xj0.3 X-j0.05/ X-X,=Xj 0.1 A. x-X,- j0.1 Xrj 0.35 nm 11 KV 20 MVA X,-j0.25 X3=j0.25 Xj0.05 110 KV Transmission X-X;-Xg=J 0.1 circuit Y B FS D X-X-j0.1 X-j 0.35 X-X-X;-j 0.1 X-X-X-J 0.1 End : DO פם Tools Mobile View Share Edit on PC School Tools 88
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,