= For the power system shown below, all reactances are given to the same base 100MVA and 33 KV. A (L-L) fault occurs on bus 2. determine: 1. Draw positive, negative. zero and the Thevenin equivalent sequence reactances networks? 2. The fault current (actual magnitude), assume the fault occurs among-phases b, c? The phase voltages at fault point during fault? - 3. T₁ G 11:33 KV Pool ΔΥ Xn System Data: G, M1, M₂ T1, T2, T3 Line X1 j0.2 p.u. 10.1 p.u. 10.1 p.u. Line X₂ j0.2 p.u. j0. 1. p.u. j0.1 p.u. 1-3 T2 33: 11 KV Xo j0.1 p.u. j0.1 p.u. j0.3 p.u. T3. 33: II KV Ă M₁ M₂ , Xn ym yn Xn j0.05 p.u. (G, M₂)

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter7: Symmetrical Faults
Section: Chapter Questions
Problem 7.2MCQ: Even though the fault current is not symmetrical and not strictly periodic, the rms asymmetrical...
icon
Related questions
icon
Concept explainers
Question
100%
= For the power system shown below, all reactances are given to the same base 100MVA and 33 KV. A
(L-L) fault occurs on bus 2. determine:
1. Draw positive, negative. zero and the Thevenin equivalent sequence reactances networks?
2. The fault current (actual magnitude), assume the fault occurs among-phases b, c?
3. The phase voltages at fault point during fault? -
T₁
G
11:33 KV
Pool
Xn
Xammy (
ΔΥ
System Data:
G, M1, M₂
T1, T2, T3
Line
X1
10.2 p.u.
10.1 p.u.
j0.1 p.u.
Line
X₂
j0.2 p.u.
j0. 1. p.u.
j0.1 p.u.
1-3
Xo
j0.1 p.u.
j0.1 p.u.
j0.3 p.u.
T₂
33: 11 KV
A
T3.
33: 11 KV
नै
Y
, Xn
(M₁) Yom
M₂Yz
Xn
j0.05 p.u. (G, M₂)
Transcribed Image Text:= For the power system shown below, all reactances are given to the same base 100MVA and 33 KV. A (L-L) fault occurs on bus 2. determine: 1. Draw positive, negative. zero and the Thevenin equivalent sequence reactances networks? 2. The fault current (actual magnitude), assume the fault occurs among-phases b, c? 3. The phase voltages at fault point during fault? - T₁ G 11:33 KV Pool Xn Xammy ( ΔΥ System Data: G, M1, M₂ T1, T2, T3 Line X1 10.2 p.u. 10.1 p.u. j0.1 p.u. Line X₂ j0.2 p.u. j0. 1. p.u. j0.1 p.u. 1-3 Xo j0.1 p.u. j0.1 p.u. j0.3 p.u. T₂ 33: 11 KV A T3. 33: 11 KV नै Y , Xn (M₁) Yom M₂Yz Xn j0.05 p.u. (G, M₂)
Expert Solution
steps

Step by step

Solved in 8 steps with 8 images

Blurred answer
Knowledge Booster
Fault analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning