A refrigeration system using refrigerant 22 is to have a refrigerating capacity of 60 TR. The evaporating temperature is is -100 C and the condensing temperature is 420 C. Enthalpy of condenser entrance is 439.25 kJ/kg.
- determine mass of refrigerant
-
Determine heat rejected in the condenser
-
volume flow at suction
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution
Trending nowThis is a popular solution!
Step by stepSolved in 2 steps with 2 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The typical difference in temperature between the cooling tower water supplied to the condenser and the out-door wet-bulb temperature is _____F.arrow_forwardFour methods for controlling head pressure in an air-cooled condenser are ______, ______, _______, andarrow_forwardThe food storage room requires a cooling system with a capacity of 10 tons of refrigeration that operates at an evaporator temperature of -17.8 ° C and a condenser temperature of 30.1 ° C. The refrigerant used is R-717 and the system operates in saturated conditions. Determine C.O.P , Refrigerant flow rate , Heat loss rate in condensesarrow_forward
- The food storage room requires a cooling system with a capacity of 15 tons of refrigeration that operates at an evaporator temperature of -17.5 Celsius and a condenser temperature of 38.9 degrees Celsius. The refrigerant used is R-134a and the system operates in saturated conditions. Determine C.O.P, refrigerant flow rate and heat loss rate in the condenser.arrow_forwardA water tube boiler produces 250,000 pounds of steam per hour at 1200 psia and1000OF from feed water entering the boiler at 1500 psia and 360oF. Fuel oil havinga higher heating value of 18,200 Btu/lb is supplied to the burners at the rate of20,700 lb/hr. Furnace volume is 1500 cubic feet. Calculate the equivalentevaporation, lb/hrA. 300,117 B. 300,317 C. 300,517 D. 300,717arrow_forwardAn ammonia refrigerator operates between evaporating and condensing temperatures of –20 and 50 oC. The vapour is dry saturated at the compressor inlet, and there is no undercooling of the condensate. Calculate: (i) the refrigerating effect. (ii) the mass flow rate per kilowatt of refrigeration capacityarrow_forward
- A water temperature rise of 18degF in the water cooled condenser isequivalent in degC to: ?the asnwer is 10 but dont know the solution pls help.arrow_forwardA two-stage R-22 system uses flash-gas remoal and intercooling as in the previous problem. The evaporating temperature is -40 C and the condensing temperature is 30 C. The pumping capacity of the high and low stage compressors is shown below: (from picture solve a and b)arrow_forwardThe food storage room requires a cooling system with a capacity of 10 tons of refrigeration that operates at an evaporator temperature of -17,8°C and a condenser temperature of 30,1°C. the refrigerant used is R-717 and the system operates in saturated conditions. A. COP= B. Refrigerant flow rate=... Kg/s C. Heat loss rate in condenser=... KJ/sarrow_forward
- A manufacturing company is intending to use its water cooled condenser for itsproposed cold storage room. The name plate of the condenser gives the followingspecifications:refrigerant ammoniacondenser water inlet 30 OCcondenser water outlet 40 OCcondensing temperature 35 OCrefrigerant flow 3.84 kg/mincirculating water flow 120 kg/minIf the company decided to purchase a new compressor and evaporator, find the tonnageof the system and the temperature in the evaporator, (b) what is the COP? (c) find thetheoretical hp required.arrow_forwarda freon 12 vapour compression system operating at a condenser temperature of 40 degree centigrade and an evaporative temperature of 0 degree centigrade develops 15 tons of refrigeration. using P-H diagram for freon 12, determine, a. the discharge temperature and mass flow rate of the refrigerant circulated, b. the teoretical piston displacement of the condenser and piston displacement per ton of refrigerant c. the theoretical horsepower of the compressor and horsepower per ton of the refrigerant d. the heat rejected in the condenser, and e. the Carnot COP and actual COP of the cycle.arrow_forwardDetermine the C.O.P of a simple saturated ammonia (R-717) compression refrigeration cycle. The evaporation temperature is -20°C and the condensor temperature is 40°Carrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningPrinciples of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Principles of Heat Transfer (Activate Learning wi...
Mechanical Engineering
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Cengage Learning