A mixture of species of A, B, and C is injected into a liquid chromatographic column with length of 20.0 cm. The obtained separation results are listed as follows:
Please calculate the resolution for species B and C from the data. Please keep your result to two decimal places.
The answer would be 1.22, I would need help how to get that answer

Transcribed Image Text:Species
Retention time (min)
Peak Width at Base (min)
Non-retained
3.0
A
4.8
0.41
10.3
0.92
11.5
1.04
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 3 steps

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- How can molecules with the same charge at varying amounts be separated by Ion exchange chromatography?arrow_forwardhree components in a mixture have varying distribution constants between the mobile phase and the stationary phass One of the components has a very low distribution constant, Would this component likely elute first or last and how would you design an experiment or modify the components of the separation to make it perform in the opposite manner?arrow_forwardQuestion 2: Propose a retrosynthesis and forward synthesis of the targeted molecule (on the left) using the provided starting materials (on the right). Any reagents (organic or inorganic) can be used and you may use any of the starting materials more than once along with any additional reagents. Note: all carbon atoms in the product must come from the starting materials provided. Retrosynthesis Forward Synthesis OHarrow_forward
- The data in the following table were extracted from a gas chromatographic analysis of a two- component mixture. Air nonane decane Retention time (s) 5 26 32 Peak width, baseline (s) 5 4 (i) Calculate the capacity factor, k, for the two compounds. (ii) Calculate the selectivity factor, a, for the two compounds.arrow_forwardYou run the chromatography system with paper as the stationary phase and 70% isopropanol as the mobile phase. You determine the Rf of a polar analyte to be 0.40. If you use 100% isopropanol (a less polar solvent) instead of isopropanol as the mobile phase what would you expect to happen to the Rf value? No value effect on Rf higher lower could be higher or lowerarrow_forwardFor quantitative analysis with gas chromatography: O the area of a peak reported by the instrument for a compound is proportional to the quantity of that compound. O the calculated response factor value for a compound is proportional to the quantity of that compound. O the retention time reported by the instrument for a compound is proportional to the quantity of that compound. O the peak height reported by the instrument for a compound is inversely proportional to the quantity of that compound. O the peak shape reported by the instrument for a compound is proportional to the quantity of that compound.arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- ChemistryChemistryISBN:9781305957404Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCostePublisher:Cengage LearningChemistryChemistryISBN:9781259911156Author:Raymond Chang Dr., Jason Overby ProfessorPublisher:McGraw-Hill EducationPrinciples of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
- Organic ChemistryChemistryISBN:9780078021558Author:Janice Gorzynski Smith Dr.Publisher:McGraw-Hill EducationChemistry: Principles and ReactionsChemistryISBN:9781305079373Author:William L. Masterton, Cecile N. HurleyPublisher:Cengage LearningElementary Principles of Chemical Processes, Bind...ChemistryISBN:9781118431221Author:Richard M. Felder, Ronald W. Rousseau, Lisa G. BullardPublisher:WILEY

Chemistry
Chemistry
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Cengage Learning

Chemistry
Chemistry
ISBN:9781259911156
Author:Raymond Chang Dr., Jason Overby Professor
Publisher:McGraw-Hill Education

Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning

Organic Chemistry
Chemistry
ISBN:9780078021558
Author:Janice Gorzynski Smith Dr.
Publisher:McGraw-Hill Education

Chemistry: Principles and Reactions
Chemistry
ISBN:9781305079373
Author:William L. Masterton, Cecile N. Hurley
Publisher:Cengage Learning

Elementary Principles of Chemical Processes, Bind...
Chemistry
ISBN:9781118431221
Author:Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:WILEY