A centrifugal exhauster is takin in dry air from a room where the temperature is 60 °F and the barometer is normal. The axis of the horizontal discharge pipe (12 inch inside diameter) is 1 ft. above that of the intake pipe (16 in inside diameter). The air in the discharge pipe is at a pressure of 1.2 in of water above normal barometric pressure. The air then flows through a meter and the rate flow is found to be 2.5 lb/s. The power input to the drive shaft of the exhausted is 8 hp. Neglecting the heat exchange with the room, calculate the temperature (in °F) of the air in the discharge pipe?

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
A centrifugal exhauster is takin in dry air from a room where the temperature is 60 °F and the barometer is normal. The
axis of the horizontal discharge pipe (12 inch inside diameter) is 1 ft. above that of the intake pipe (16 in inside
diameter). The air in the discharge pipe is at a pressure of 1.2 in of water above normal barometric pressure. The air
then flows through a meter and the rate flow is found to be 2.5 lb/s. The power input to the drive shaft of the exhausted
is 8 hp. Neglecting the heat exchange with the room, calculate the temperature (in °F) of the air in the discharge pipe?
Transcribed Image Text:A centrifugal exhauster is takin in dry air from a room where the temperature is 60 °F and the barometer is normal. The axis of the horizontal discharge pipe (12 inch inside diameter) is 1 ft. above that of the intake pipe (16 in inside diameter). The air in the discharge pipe is at a pressure of 1.2 in of water above normal barometric pressure. The air then flows through a meter and the rate flow is found to be 2.5 lb/s. The power input to the drive shaft of the exhausted is 8 hp. Neglecting the heat exchange with the room, calculate the temperature (in °F) of the air in the discharge pipe?
Expert Solution
steps

Step by step

Solved in 5 steps with 15 images

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The