A balanced 3 phase Y connected generator with negative sequence has an impedance of 0.3+j0.5 QVO and an internal voltage of 150 V/ 0 (rms). The generator feeds a balanced 3 phase Y connected load having an impedance of 24+ j35 QD. The impedance of the line connecting the generator to the load is 0.7 + jl.5 VO. The a-phase internal voltage of the generator is specified as the reference phasor. i. Construct the a-phase equivalent circuit of the system. ii. Calculate the three line currents: lar, Ibs and Iec. Calculate the three phase voltages at the load: Van, Vav and Ven Calculate the line voltages: VAB, VBc and Vca at the terminals of the load. Calculate the total complex power at the load, Sr. ii. iv. V.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.16P: A single-phase, 120V(rms),60Hz source supplies power to a series R-L circuit consisting of R=10 and...
icon
Related questions
icon
Concept explainers
Question
A balanced 3 phase Y connected generator with negative sequence has an impedance of
0.3+j0.5 QVO and an internal voltage of 150 V/ 0 (rms). The generator feeds a balanced 3
phase Y connected load having an impedance of 24+ j35 QD. The impedance of the line
connecting the generator to the load is 0.7 + jl.5 VO. The a-phase internal voltage of the
generator is specified as the reference phasor.
i. Construct the a-phase equivalent circuit of the system.
ii. Calculate the three line currents: lar, Ibs and Iec.
Calculate the three phase voltages at the load: Van, Vav and Ven
Calculate the line voltages: VAB, VBc and Vca at the terminals of the load.
Calculate the total complex power at the load, Sr.
ii.
iv.
V.
Transcribed Image Text:A balanced 3 phase Y connected generator with negative sequence has an impedance of 0.3+j0.5 QVO and an internal voltage of 150 V/ 0 (rms). The generator feeds a balanced 3 phase Y connected load having an impedance of 24+ j35 QD. The impedance of the line connecting the generator to the load is 0.7 + jl.5 VO. The a-phase internal voltage of the generator is specified as the reference phasor. i. Construct the a-phase equivalent circuit of the system. ii. Calculate the three line currents: lar, Ibs and Iec. Calculate the three phase voltages at the load: Van, Vav and Ven Calculate the line voltages: VAB, VBc and Vca at the terminals of the load. Calculate the total complex power at the load, Sr. ii. iv. V.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning