A 50 kW, 200 V differentially compounded generator has NSE of 10 turns, NF of 3000 turns, and RF of 70 Ω. Calculate the value of the magnetomotive force at no-load and full-load operating conditions.
Synchronous Generator
In comparison to an asynchronous generator, it is a machine where the rotor speed is equal to the rotating magnetic field produced by the stator, i.e., mechanical speed is equal to the electrical speed, thus called synchronous, and not asynchronous.
Salient Pole Rotor
Salient pole rotor includes a large number of exposed poles mounted on a magnetic wheel. The construction of a bright pole is as shown in the image on the left. The proposed poles are made of metal laminations. The rotor winding is provided on these poles and is supported by pole shoes.
Q2/
A 50 kW, 200 V differentially compounded generator has NSE of 10 turns, NF of 3000 turns, and
RF of 70 Ω. Calculate the value of the magnetomotive force at no-load and full-load operating
conditions.
Step by step