A 20 ft by 24 ft office has a 14 ft ceiling height, with room surface reflectances of 80% ceiling, 50% walls, and 20% floor. Technical information for the luminaire that you selected to light this space is shown below, and from that you have determined that each luminaire has 4500 lumens. The luminaires are pendant mounted and hang 2 ft below the ceiling. How many luminaires are needed to produce an average of 30 footcandles on the desks (30" AFF) in the office? Show your work and keep track of units as you set up and solve the equations. Specifically, show the values of the RCR and CU as part of your work.

EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN:9781337516549
Author:Simmons
Publisher:Simmons
Chapter7: Luminaires, Ballasts, And Lamps
Section: Chapter Questions
Problem 20R: Circle the correct answer for the following statements. a. When selecting a trim for a recessed...
icon
Related questions
Question
-)
A 20 ft by 24 ft office has a 14 ft ceiling height, with room surface reflectances of 80% ceiling, 50%
walls, and 20% floor. Technical information for the luminaire that you selected to light this space is
shown below, and from that you have determined that each luminaire has 4500 lumens. The
luminaires are pendant mounted and hang 2 ft below the ceiling. How many luminaires are
needed to produce an average of 30 footcandles on the desks (30" AFF) in the office? Show your
work and keep track of units as you set up and solve the equations. Specifically, show the values of
the RCR and CU as part of your work.
Transcribed Image Text:-) A 20 ft by 24 ft office has a 14 ft ceiling height, with room surface reflectances of 80% ceiling, 50% walls, and 20% floor. Technical information for the luminaire that you selected to light this space is shown below, and from that you have determined that each luminaire has 4500 lumens. The luminaires are pendant mounted and hang 2 ft below the ceiling. How many luminaires are needed to produce an average of 30 footcandles on the desks (30" AFF) in the office? Show your work and keep track of units as you set up and solve the equations. Specifically, show the values of the RCR and CU as part of your work.
Catalog #
Project
LKW for
This lomatice
Comments
Prepared by
C2-30.1T5
APPEARATHO
4500 Lemens
Efficiency 90.9%
Test Report
TL5:17895
Coefficients of Utilization
AGA
0
NATDONI 2 9
Effective floor cavity reflectance
70 50 30 10 70 50 30 10
Zonal Lumen Summary
Lumens Limp Fixture
5509
CORELITE™
2009
10000
MAA
D
DE P
Type
Date
Angle
in Del
PEN
N!!!
3100
P
50 30 10 50 30
JE TE JE
57 55- 54 411 41
51 48 15
45 12 30
41 37 31
332
33:29 26
Luminance Data
MODE
0 Dig 45 Dog
CUSM
2810
14320
31 28 27
20-25-9
25-24 21
23-20 18
27-20-20-2018 16
24 2017 10 0 10
925 18-16 2017-10- 1255 12-11 78
POT
MP BE
102
P
201
29-31 J
78 25 24
24 25 2
P
20-TE 1
18 17 15
17-15-0
15-12-19
IQ
D
252523CÓÓÓÓĆ
Candela
Angle
0
5
85
15
TE
15
15
Element
Along II
44-4
125
720
FIT
151
Transcribed Image Text:Catalog # Project LKW for This lomatice Comments Prepared by C2-30.1T5 APPEARATHO 4500 Lemens Efficiency 90.9% Test Report TL5:17895 Coefficients of Utilization AGA 0 NATDONI 2 9 Effective floor cavity reflectance 70 50 30 10 70 50 30 10 Zonal Lumen Summary Lumens Limp Fixture 5509 CORELITE™ 2009 10000 MAA D DE P Type Date Angle in Del PEN N!!! 3100 P 50 30 10 50 30 JE TE JE 57 55- 54 411 41 51 48 15 45 12 30 41 37 31 332 33:29 26 Luminance Data MODE 0 Dig 45 Dog CUSM 2810 14320 31 28 27 20-25-9 25-24 21 23-20 18 27-20-20-2018 16 24 2017 10 0 10 925 18-16 2017-10- 1255 12-11 78 POT MP BE 102 P 201 29-31 J 78 25 24 24 25 2 P 20-TE 1 18 17 15 17-15-0 15-12-19 IQ D 252523CÓÓÓÓĆ Candela Angle 0 5 85 15 TE 15 15 Element Along II 44-4 125 720 FIT 151
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 7 steps with 20 images

Blurred answer
Knowledge Booster
Electric heating unit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
EBK ELECTRICAL WIRING RESIDENTIAL
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT