Question
thumb_up100%
A 12KW, 240V 1500RPM shunt generator has an armature resistance of .02 ohm and a shunt field resistance of 160 ohms. The stray power losses are 900W. Assuming a constant shunt field current, what (1) the efficiency at rated load and (2) the efficiency of the generator at half-rated load?
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 2 steps

Knowledge Booster
Similar questions
- 3arrow_forwardPlease solve this problem step by step and illustrate your answer properly. Write your answer in a piece of paper please. Box the final answer.arrow_forwardExplain the conditions for parallel operation of synchronous generators. A three phase, wye connected, synchronous generator is rated 150 MW, 0.85 lagging power factor, 12.6 kV, 60 Hz, and 1800 rpm. Each winding has an armature resistance of 0.05Q and a synchronous reactance of 0.6Q. Draw the phasor diagram with values, show torque angle and determine the induced voltage for the condition of rated load.arrow_forward
- 5.26. A 23-kW, 230-V, 900-rpm shunt generator has 240.5 V induced in its ar- mature winding when it delivers the rated load at the rated voltage. The field current is 5 A. What is the armature resistance? What is the field- circuit resistance? The no-load voltage of the generator is 245 V. What is the voltage regulation? Why is the induced emf at the rated load not equal to that at no load?arrow_forwardA 10 kW, 250V DC, 6-pole, long-shunt generator runs at 1000 RPM when delivering full-load. The armature has 534 simplex lap connected conductors. The full-load total Cu losses are 660 W and the total brush drop is 1 volt. Determine the flux per pole if the field resistance is 250 ohms and series field resistance is 0.05 ohms.arrow_forward2. A 30-kW, 500-V dc short-shunt generator has armature, series field and shunt field winding resistances of 0.14 Q, 0.22 Q and 100 O respectively. Determine the voltage regulation at (a) 90.125% load, (b) 79.794% load and (c) 65.654% load.arrow_forward
- DC Shunt Generator No-Load Characteristics Please draw the curves for both cases and mention the scale for each on a graph paper. Please use graph paper only.arrow_forwardA three-phase, 1 MVA, 2.3 kV, 60 Hz, star-connected, salient pole synchronous generator has the d- and q-axis synchronous reactances are 1.1 and 0.8 Q respectively. Its armature has a resistance of 0.15 §. The machine is operating at full load at a power factor of 0.8 lagging. Determine the excitation voltage Ę and draw the generator phasor diagram using actual values.arrow_forward. When a self-excited compound DC generator supplies load, the terminal voltage is not the same as the generated emE Why? a) voltage drop across the armature resistance will reduce the voltage available at the load terminals b) where there is a series field, voltage drop across the series field resistance will reduce the voltage available at the load terminals c) both "a" and "b" d) neither "a" nor "b"arrow_forward
- IDENTIFY TWO WAYS IN WHICH THE OUTPUT POLARITY OF A SHUNT DC GENERATOR CAN BE CHANGED.arrow_forwardThe armature of a 6-pole separately excited dc generator is triplex wave wound with 534 conductors. This machine delivers power to the load at 200V while being driven at 900rpm. At this load, the armature circuit dissipates 640W. If the flux of this generator is 180-mWb, determine the kW rating of the load served. Assume a total brush drop of 2V.arrow_forwardA DC shunt generator has a full load output of 10kW at a terminal voltage of 240V. The armature and the shunt field winding resistances are 0.6 and 160 ohms respectively. The sum of the mechanical and core-losses is 500W. calculate the power required in kW at the driving shaft at full-load, and the corresponding efficiency and voltage regulationarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning

Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning